Logo Bihl+Wiedemann GmbH

Phoenix Contact

Product overview

In the following article overview you will find Bihl+Wiedemann products which can be used as replacement articles for Phoenix Contact products. Since Phoenix Contact no longer markets the products listed here themselves, you may source these replacement articles from us in the future.

Phoenix Contact, Overview of equivalent products: Master/Gateways

  • When using an equivalent Bihl+Wiedemann Gateway as a replacement for a Phoenix Contact Gateway, the device description file must be reinstalled.
  • The latest version of the device description file (GSD, EDS, XDD etc.) of the gateway is available in the "Downloads" section of the respective device.
Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
ASI MA PB XL AB - 2741710BWU1249
Bihl+Wiedemann Article No. BWU1249
FLX ASI MA 2PB EF - 2773607BWU1568
Bihl+Wiedemann Article No. BWU1568
FLX ASI MA PB SF - 2773597BWU1746
Bihl+Wiedemann Article No. BWU1746
ASI MA PC PCI - 2741257BW1195
Bihl+Wiedemann Article No. BW1195

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP67, M12

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different pin assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection
ASi node profile Required Master profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
FLX ASI 3.0 DIO 4/4 M12-2A - 2773474Phoenix ContactIP67, 4 x M1244 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-7.A.7.≥M21 AB addressASi profile cableBWU3144
Bihl+Wiedemann Article No. BWU3144
Bihl+WiedemannIP67, 8 x M12, EXTREME44 x electronicout of ASiout of AUXY8 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB addressASi profile cable
FLX ASI 3.0 DIO 4/4 M12-2A - 2773474Phoenix ContactIP67, 4 x M1244 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-7.A.7.≥M21 AB addressASi profile cableBWU2626
Bihl+Wiedemann Article No. BWU2626
Bihl+WiedemannIP67, 8 x M1244 x electronicout of ASiout of AUXY8 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB addressASi profile cable
FLX ASI DIO 4/3 M12-2A - 2773445Phoenix ContactIP67, 4 x M1243 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-7.A.7.2≥M31 AB addressASi profile cableBWU3375
Bihl+Wiedemann Article No. BWU3375
Bihl+WiedemannIP67, 4 x M1243 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-7.A.(7).0≥M31 AB addressASi profile cable
FLX ASI DIO 4/3 M12-2A - 2773445Phoenix ContactIP67, 4 x M1243 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-7.A.7.2≥M31 AB addressASi profile cableBWU3496
Bihl+Wiedemann Article No. BWU3496
Bihl+WiedemannIP67, 8 x M1243 x electronicout of ASiout of AUX, 2 A per outputSingle8 x M12 sockets, 5 polesS-7.A.(7).0≥M31 AB addressASi profile cable
FLX ASI DIO 2/2 M12-2A - 2773432Phoenix ContactIP67, 4 x M1222 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-B.A.2.≥M31 AB addressASi profile cableBWU3456
Bihl+Wiedemann Article No. BWU3456
Bihl+WiedemannIP67, 4 x M1222 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB addressASi profile cable
FLX ASI DIO 2/2 M12-2A - 2773432Phoenix ContactIP67, 4 x M1222 x electronicout of ASiout of AUXY4 x M12 sockets, 5 polesS-B.A.2.≥M31 AB addressASi profile cableBWU3141
Bihl+Wiedemann Article No. BWU3141
Bihl+WiedemannIP67, 4 x M1222 x electronicout of ASiout of AUXSingle4 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB addressASi profile cable

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP67, M8

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different pin assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection
ASi node profile Required Master profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix ContactIP67, 8 x M844 x electronicout of ASiout of AUXSingle8 x M8 sockets, 3 polesS-7.0.≥M21 Single addressASi via M12BW3661
Bihl+Wiedemann Article No. BW3661
Bihl+WiedemannIP67, 8 x M844 x electronicout of ASiout of AUXSingle8 x M8 sockets, 3 polesS-7.A.(7).0≥M41 AB addressASi profile cable
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix ContactIP67, 8 x M844 x electronicout of ASiout of AUXSingle8 x M8 sockets, 3 polesS-7.0.≥M21 Single addressASi via M12BWU2645
Bihl+Wiedemann Article No. BWU2645
Bihl+WiedemannIP67, 8 x M1244 x electronicout of AUXout of AUXSingle8 x M12 sockets, 5 polesS-7.A.7.7≥M41 AB addressASi via M12
FLX ASI DIO 4/4 M8-1A - 2773416Phoenix ContactIP67, 8 x M844 x electronicout of ASiout of AUXSingle8 x M8 sockets, 3 polesS-7.0.≥M21 Single addressASi via M12BWU2684
Bihl+Wiedemann Article No. BWU2684
Bihl+WiedemannIP67, 8 x M1244 x electronicout of ASiout of AUXSingle8 x M12 sockets, 5 polesS-7.0.(F).E≥M01 Single addressASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single addressASi via M12BWU2620
Bihl+Wiedemann Article No. BWU2620
Bihl+WiedemannIP67, 4 x M124-out of ASi-Single4 x M12 sockets, 5 polesS-0.A.(7).E≥M31 AB addressASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single addressASi via M12BW3661
Bihl+Wiedemann Article No. BW3661
Bihl+WiedemannIP67, 8 x M844 x electronicout of ASiout of AUXSingle8 x M8 sockets, 3 polesS-7.A.(7).0≥M41 AB addressASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single addressASi via M12BW3521
Bihl+Wiedemann Article No. BW3521
Bihl+WiedemannIP67, 8 x M88-out of ASi-Single8 x M8 sockets, 3 polesS1-0.A.(7).E, S2-0.A.(6).E≥M32 AB addressesASi profile cable
FLX ASI DI 4 M8 - 2773403Phoenix ContactIP67, 8 x M84-out of ASi-Single8 x M8 sockets, 3 polesS-0.0.≥M21 Single addressASi via M12BWU3457
Bihl+Wiedemann Article No. BWU3457
Bihl+WiedemannIP67, 4 x M124-out of ASi-Single4 x M12 sockets, 5 polesS-0.A.(7).E≥M31 AB addressASi via M12

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP20

  • + Same number I/Os
  • + Same protection rating
  • + Same dimensions/housing
  • + Same node profile
  • + Same required master profile
  • ‒ Different terminal assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection
ASi node profile Required Master profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
ASI IO SV DIO 4/3 ABPhoenix ContactIP20, 22,5 mm x 92 mm, 4 x 4 contacts43 x electronicout of AUXout of AUXpush in terminalsS-7.A.(7).E≥M31 AB addressclampsBWU4183
Bihl+Wiedemann Article No. BWU4183
Bihl+WiedemannIP20, 22,5 mm x 92 mm, 4 x 4 contacts43 x electronicout of AUXout of AUXpush in terminalsS-7.A.(7).E≥M31 AB addressclamps

 

 

Phoenix Contact, Overview of functionally equivalent products: Digital Modules ASi, IP20

  • + Same number I/Os
  • + Same protection rating
  • ‒ Different dimensions/housing
  • ‒ Different node profile
  • ‒ Different required master profile
  • ‒ Different terminal assignment
Phoenix Contact Article No. Manufacturer Type Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection
ASi node profile Required Master profile

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection
Bihl+Wiedemann
Article No.
Figure
ASI IO ME DI 4 AB - 2741671Phoenix ContactIP20, 25 mm x 105 mm, 6 x 4 contacts4-selectable, out of ASi or out of AUX, Default out of ASi-push in terminalsS-0.A.0.≥M41 AB addressclampsBWU3265
Bihl+Wiedemann Article No. BWU3265
Bihl+WiedemannIP20, 22,5 mm x 114 mm, 4 x 4 contacts4-out of ASi-push in terminalsS-7.A.(7).E≥M31 AB addressclamps
ASI IO ME DI 4 AB - 2741671Phoenix ContactIP20, 25 mm x 105 mm, 6 x 4 contacts4-selectable, out of ASi or out of AUX, Default out of ASi-push in terminalsS-0.A.0.≥M41 AB addressclampsBWU3266
Bihl+Wiedemann Article No. BWU3266
Bihl+WiedemannIP20, 22,5 mm x 114 mm, 4 x 4 contacts4-out of AUX-push in terminalsS-7.A.(7).E≥M31 AB addressclamps

 

 

Phoenix Contact, Overview of functionally equivalent products: Power Supply

  • ‒ No earth fault and EMC monitor integrated in the power supply, all current Bihl + Wiedemann gateways have an integrated earth fault and EMC monitor
Phoenix Contact Article No. Manufacturer

"ASi power supply":

Special power supplies with integrated data decoupling unit for use in ASi-3 only networks. Suitable for all Bihl+Wiedemann ASi-3 gateways and safety monitors.

"30 V power supply":

Inexpensive standard power supplies, suitable as an alternative for use with ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi gateways.


30 V power supply, optimized for ASi-5/ASi-3:

Inexpensive standard power supplies, optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated data decoupling unit (version "1 power supply , 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


30 V power supply, optimized for ASi-5/ASi-3, NEC class 2 :

The 30 V/3 A power supply is UL certified, has power limitation <100 W and is designed for use in NEC class 2 networks. It is suitable for applications with 1 power supply per ASi network. In the case of power intensive applications, Bihl+Wiedemann recommends the use of a 30 V power supply without 100 W power limitation in combination with a power limitation module (BWU4189) for each ASi network.The power supply is optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated decoupling coils (version "1 power supplies, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 V ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.


"ASi power supply decoupling unit":

Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling.


"Power decoupling unit":

Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A.

Power supply
Input voltage Output current

"IP20":
Protected against solid foreign bodies having a diameter of 12.5 mm or larger and against finger contact, not protected against water.


"IP40":

Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water.

"IP54":

Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.


"IP65":
Dust-tight, full protection against contact, protection against spray water (jet) from any angle.

"IP67":

Dust-tight, full protection against contact, protection against temporary immersion.

Protection rating
Bihl+Wiedemann
Article No.
Figure
ASI QUINT 100-240/4.8 EFD - 2736699Phoenix ContactASi power supply100 ... 240 VAC, 1 phase4,8 AIP20BW1649
Bihl+Wiedemann Article No. BW1649
Bihl+WiedemannASi power supply90 ... 265 VAC, wide range supply4 AIP20

 

 

Phoenix Contact, Overview of equivalent products: Diagnostics/Commissioning

  • ASi Address Programming Device
  • Accessories for ASi Address Programming Device
  • Master Simulators
Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
ASI CC ADR - 2741338BW1191
Bihl+Wiedemann Article No. BW1191
ASI CC ADR CAB CINCH - 2741341BW1802
Bihl+Wiedemann Article No. BW1802
PB ECO LINK - 2741480BW1131
Bihl+Wiedemann Article No. BW1131

 

 

Phoenix Contact, Overview of equivalent products: Software

Phoenix Contact Article No. Bihl+Wiedemann
Article No.
Figure
AS-i Control ToolBW1203
Bihl+Wiedemann Article No. BW1203