ASi Modules with integrated IO-Link Masters

With the ASi modules with integrated IO-Link masters from Bihl+Wiedemann intelligent IO-Link sensors and actuators can now be easily incorporated into ASi – exactly there, where they are needed. The IO-Link sensors can be easily parametrized using the configuration tool from Bihl+Wiedemann.

In many application scenarios, IO-Link solutions from Bihl+Wiedemann are much more cost-efficient than similar solutions from other providers. An application with Bihl+Wiedemann is already cheaper than comparable PROFINET variants from three 4-port IO-Link masters. Another factor is the finer granularity. Our 1-port IO-Link master allows you to integrate an IO-Link device exactly where you need it. Thanks to cable-piercing technology, it is extremely easy to install our IO-Link master. You can substantially reduce the time required for assembly.

 

ASi Modules with integrated IO-Link Masters: IP67, M12

  • IO-Link ports class A
  • IO-Link ports class B
  • IP67, M12: 2 x 2 connectors for profile cable
Figure Model Number of IO-Link Ports

Port class A (M12): Pin 4 configurable (IO-Link/DI/DO), additional digital input at pin 2. Compatible with 3 pol IO-Link devices (M8).

Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8).

IO-Link Port Class A

Port class B (M12): Pin 4 configurable (IO-Link/DI/DO), additional power supply (galvanically isolated) for IO-Link devices at pins 2 and 5. Compatible with 3 pol IO-Link devices (M8).

Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8).

IO-Link Port Class B

IO-Link and additional inputs/outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs can neither be connected to earth nor to external potential.

Sensor supply (IO-Link supply and input/output supply)

Connection via M12: For IO-Link ports class B the supply of actuators is provided by an additional (galvanically isolated) power supply by AUX (auxiliary 24 V power) via Pin 2 (P24) and Pin 5 (N24).

Connection via clamps: If connected IO-Link Devices with IO-Link ports class B need a higher current consumption, additionally they can be supplied directly via the power supply.

Actuator supply (for IO-Link ports class B)

COM1 = 4.8 kBaud

COM2 = 38.4 kBaud

COM3 = 230.4 kBaud (optional according to Specification V1.0)

 

An IO-Link device supports only one of the defined data transmission rates.

According to Specification V1.1, the IO-Link master supports all data transmission rates and adapts itself automatically to the data transmission rate supported by the device.

IO-Link data rate
IO-Link specification

The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).


Line protection: If the module is supplied via a M12 connection with A or B coding, it may only be used with a current load of max. 4 A per pin in acc. with IEC 61076-2-101 and IEC 61076-2-109. A fused tap is recommended. There is no such limitation for modules supplied via piercing contacts.

ASi connection

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BWU4067ASi module with integrated IO-Link master422out of AUXout of AUXCOM1 / COM2 / COM3V1.1ASi profile cable1 ASi-5 address
BWU3897ASi module with integrated IO-Link master422out of AUXout of AUXCOM1 / COM2 / COM3V1.1ASi via M121 ASi-5 address
BWU3819ASi module with integrated IO-Link master44-out of AUX-COM1 / COM2 / COM3V1.1ASi profile cable1 ASi-5 address
BWU3899ASi module with integrated IO-Link master44-out of AUX-COM1 / COM2 / COM3V1.1ASi via M121 ASi-5 address
BW4211Starter Kits422out of AUXout of AUXCOM1 / COM2 / COM3V1.1ASi profile cable1 ASi-5 address
BW4229Starter Kits422out of AUXout of AUXCOM1 / COM2 / COM3V1.1ASi profile cable1 ASi-5 address