PROFINET Fieldbus system
PROFINET Products
PROFINET ASi Gateways
ASi PROFINET gateways in stainless steel provide an interface for a PROFINET fieldbus. These certified ASi gateways are available in various versions with IP20 protection rating.
PROFINET ASi
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|
![]() | PROFINET ASi-5/ASi-3 | Gateway | IP20 | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3852ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 2 masters |
![]() | PROFINET ASi-5/ASi-3 | Gateway | IP20 | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 8 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3848ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
![]() | PROFINET ASi | Gateway | IP20 | PROFINET, OPC UA | 2 ASi networks, 2 ASi Masters | yes, max. 4 A/ASi network | Ethernet fieldbus | yes | yes | optional | BWU3759ASi-3 PROFINET Gateway in Stainless Steel, 2 masters |
![]() | PROFINET ASi | Gateway | IP20 | PROFINET, OPC UA | 2 ASi networks, 2 ASi Masters | no, max. 8 A/ASi network, redundant supply | Ethernet fieldbus | yes | yes | optional | BWU3844ASi-3 PROFINET Gateway in Stainless Steel, 2 masters |
![]() | PROFINET ASi | Gateway | IP20 | PROFINET, OPC UA | 1 ASi network, 1 ASi Master | no, max. 8 A/ASi network | Ethernet fieldbus | yes | yes | optional | BWU3758ASi-3 PROFINET Gateway in Stainless Steel, 1 master |
![]() | PROFINET ASi | Gateway | IP20 | PROFINET | 1 ASi network, 1 ASi Master | no, max. 8 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3431ASi-3 PROFINET Gateway in Stainless Steel, 1 master |
![]() | 24 Volt ASi-5/ASi-3 Gateway | Gateway | IP20 | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus | yes | yes | no | BWU384724 Volt ASi-5/ASi-3 PROFINET Gateway in Stainless Steel, 1 ASi-5/ASi-3 master |
Safety, PROFINET ASi
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs Safety, SIL 3, Cat. 4 | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | PROFIsafe, PROFINET, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | BWU3674ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | PROFIsafe, PROFINET, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | BWU3862ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() | Safety, PROFINET ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | BWU3863ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() | Safety, PROFINET | Gateway with integrated Safety Monitor | IP20 | PROFINET | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | 6 | 3 x 2 channels | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | BWU2798ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi master |
The PROFINET Master Simulator is an easy to use software for data exchange with PROFINET Slaves of many suppliers.
The PROFINET Master Simulator can exchange data with many PROFINET Slaves even without a PROFINET Master. Furthermore the PROFINET Master Simulator also processes GSD-files as well as the input of special configurations to start the data exchange with PROFINET Slaves. Identification, renaming and address assignment of PROFINET Slaves is also possible.
Furthermore, the data, in particular the diagnostic function can be displayed binary, hexadecimal and now also as ASCII code. Output data can be transmitted consistently. In type mode it is possible to set an output as long as the mouse button is pressed.
In addition BW3057 supports PROFIsafe modules, as well as a log function of the I/O data and allows operations in the acyclic mode (Record Data CR).
However as the PROFINET Master Simulator is a monitoring and commissioning tool for PROFINET Slaves, it is not designed to control automation processes.
PROFINET Master Simulator
Figure | Type | PROFIsafe | Log function of I/O data | Sending of acyclic data | Article No. |
---|---|---|---|---|---|
![]() | PROFINET Master Simulator | yes | yes | yes | BW3649PROFINET Master Simulator Plus DLL Kit |
![]() | PROFINET Master Simulator | yes | yes | yes | BW3057PROFINET Master Simulator Plus |
![]() | PROFINET Master Simulator | no | no | no | BW3035PROFINET Master Simulator |