Active distributors ASi from Bihl+Wiedemann allow you to make any sensor or actuator AS-Interface capable. Even modules without their own ASi terminal can be easily integrated into an existing ASi network using these active distributors ASi. Other features include individually configurable connection options using M8 or M12 connectors, flying leads or push-in termimals to conform to the customer’s application, as well as a compact form factor, making them ideal for use in cable ducts.

 

Active Distributors ASi, IP67/IP54

  • up to 8 cable connections
  • round cable/connecting wires
  • ASi addressing cable socket
  • M8 cable sockets, straight
  • M12 cable sockets, straight/angled
Figure Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Profile cable connection

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Special function Article No.
BWU367544 x electronicout of ASiout of AUX8 x M12 cable sockets, straight, 5 poles + 1 x ASi addressing cable socketSingleI1/O4: 0,35 m, I2/O3: 0,25 m, I3/O2: 0,15 m, I4/O1: 0,05 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB address-
BWU367644 x electronicout of AUXout of AUX3 x M12 cable sockets, straight, 5 poles + 2 x M8 snap-in cable sockets, straight, 4 poles + 1 x ASi addressing cable socket-I1/I2: 0,1 m, I3/I4: 0,3 m, O1/O2: 0,2 m, O3/O4: 0,3 myes, depth: 35 mm1 x ASi1 AB address-
BWU378644 x electronicout of ASiout of AUX4 x M12 cable sockets, straight, 5 polesSingle2 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB address-
BWU357742 x electronicout of ASiout of ASi6 x M8 cable sockets, straight, 4 poles-I: 0,15 m, O: 0,50 myes, depth: 35 mm1 x ASi1 AB addressoptimized to control valves Festo CPE14 / VUVG-L14 via ASi
BWU355544 x electronicout of ASiout of AUX4 x M8 cable sockets, straight, 4 polesY0,20 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB address-
BWU369522 x electronicout of ASiout of ASi2 x M12 cable sockets, straight, 5 poles + 2 x M8 cable socket, straight, 3 polesSingleI: 0,20 m, O: 0,40 myes, depth: 35 mm1 x ASi1 AB address-
BWU36334-out of ASi-4 x M12 cable sockets, straight, 5 polesSingle2 myes, depth: 35 mm1 x ASi1 AB address-
BWU36324-out of ASi-4 x M12 cable sockets, straight, 5 polesSingle0,30 myes, depth: 35 mm1 x ASi1 AB address-
BWU37304-out of ASi-4 x M12 cable socket, straight, 5 poles + 1 x ASi addressing cable socketSingleI1: 0,35 m, I2: 0,25 m, I3: 0,15 m, I4: 0,05 myes, depth: 35 mm1 x ASi1 AB address-
BWU36084-out of AUX-3 x round cable/connecting wires + 1 x M8 cable socket, straight, 4 poles-1 myes, depth: 35 mm-1 AB address-
BWU4727up to 4, depending on configurationup to 4 x electronic, depending on configurationout of AUXout of AUX2 x M12 cable sockets, straight, 5 polesY/mixed, depending on configuration1 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB address-
BWU417244 x electronicout of ASiout of AUX4 x round cable/connecting wires-1 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB address-
BWU331744 x electronicout of ASiout of AUX2 x round cables/connecting wires-1 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB address-
BW350744 x electronicout of ASiout of AUX2 x M12 cable sockets, straight, 5 poles-1 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB address-
BWU332644 x electronicout of ASiout of ASi2 x round cables/connecting wires-1 myes, depth: 35 mm1 x ASi1 AB address-
BWU378534 x electronicout of AUXout of AUX2 x M12 cable sockets, straight, 5 poles-X1: 0,25 m, X2: 2 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB addressto connect K50Pro Banner Stacklight to ASi
BWU33744-out of ASi-2 x round cables/connecting wires-0,50 myes, depth: 35 mm1 x ASi1 AB address-
BWU353414 x electronicout of ASiout of ASi1 x M12 cable socket, straight, 5 poles + 1 x M12 cable socket, angled, 5 poles-0,30 myes, depth: 35 mm1 x ASi1 AB addressto connect Banner K50 Series EZ-Light, type K50L...PQ + Wenglor light curtains Pick-to-Light
BWU3729-4 x electronic-out of ASi1 x round cable/connecting wires + 1 x ASi addressing cable socket-4 myes, depth: 35 mm1 x ASi1 AB address-
BW350044 x electronicout of ASiout of ASi1 x round cable/connecting wires-5 myes, depth: 35 mm1 x ASi1 AB address-
BWU360644 x electronicout of ASiout of ASi1 x round cable/connecting wires-2 myes, depth: 35 mm-1 AB addressto connect Stack-Light Banner TL50GYRAQ + audible alarm (180 mA) to ASi
BW337744 x electronicout of AUXout of AUX1 x M12 cable socket, straight, 8 poles-1 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB addressto connect Euchner MGB to ASi
BWU478422 x electronicout of AUXout of AUX1 x M12 cable socket, straight, 8 poles-1 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB addressto control Linak LA12 drives
BWU360722 x electronicout of AUXout of AUX1 x round cable/connecting wires-3 myes, depth: 35 mm1 x ASi, 1 x AUX1 AB addressto control Linak LA12 drives
BWU363913 x electronicout of ASiout of ASi1 x M12 cable socket, angled, 8 poles-0,30 myes, depth: 35 mm1 x ASi1 AB addressto connect Banner K50 Series EZ-LIGHT, Typ K50AP...F2Q to ASi
BWU34984-out of AUX-2 x M12 cable sockets, straight, 5 polesY0,40 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU362822 x electronicout of AUXout of AUX1 x round cable/connecting wires + 1 x M12 cable sockets, straight, 5 polesYI: 0,4 m, O: 1,5 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU349722 x electronicout of AUXout of AUX2 x M12 cable sockets, straight, 5 polesY0,40 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU360222 x electronicout of AUXout of AUX2 x round cables/connecting wires-1 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU487921 x electronicout of AUXout of AUX1 x M12 cable socket, straight, 5 poles + 1 x round cable/connecting wiresSingle1 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU325021 x electronicout of AUXout of AUX2 x M12 cable sockets, angled, 5 poles1 x Y + 1 x Mixed1 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU340022 x electronicout of ASiout of ASi1 x M12 cable socket, straight, 8 poles-1 myes, depth: 19 mm1 x ASi1 AB address-
BWU36422-out of ASi-1 x M12 cable socket, angled, 5 polesY1 myes, depth: 19 mm1 x ASi1 AB address-
BWU35642-out of AUX-1 x M12 cable socket, angled, 5 polesY1 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BW3300-4 x electronic-out of AUX1 x round cable/connecting wires-1 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU3487-4 x electronic-out of AUX1 x round cable/connecting wires-5 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU4766-4 x electronic-out of AUX1 x round cable/connecting wires-3 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU3788-4 x electronic-out of AUX1 x M12 cable socket, straight, 5 poles-5 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU3712-4 x electronic-out of AUX1 x M12 cable socket, straight, 5 poles-3 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU4763-4 x electronic-out of AUX1 x M12 cable socket, straight, 5 poles-10 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB address-
BWU4087-4 x electronic-out of AUX1 x M12 cable socket, straight, 5 poles-2 myes, depth: 19 mm1 x ASi, 1 x AUX1 AB addressto connect general-purpose display banner K50 Pro to ASi

 

 

Active Distributor ASi, IP20

  • 8 x push in teminals
  • wire section max. 0,5 mm²/AWG20
Figure Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Profile cable connection

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BWU33494-out of AUX-8 x push in terminalsyes, depth: 19 mm1 x ASi, 1 x AUX1 AB address
BWU341431 x electronicout of AUXout of AUX8 x push in terminalsyes, depth: 19 mm1 x ASi, 1 x AUX1 AB address
BWU3342-4 x electronic-out of AUX8 x push in terminalsyes, depth: 19 mm1 x ASi, 1 x AUX1 AB address

 

 

ASi Slaves/IO-Link Master: Active Distributors, IP67

  • IO-Link ports class A
  • IO-Link ports class B
Figure Model Number of IO-Link Ports

Port class A (M12): Pin 4 configurable (IO-Link/DI/DO), additional digital input at pin 2. Compatible with 3 pol IO-Link devices (M8).

Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8).

IO-Link Port Class A

Port class B (M12): Pin 4 configurable (IO-Link/DI/DO), additional power supply (galvanically isolated) for IO-Link devices at pins 2 and 5. Compatible with 3 pol IO-Link devices (M8).

Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8).

IO-Link Port Class B

IO-Link and additional inputs/outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs can neither be connected to earth nor to external potential.

Sensor supply (IO-Link supply and input/output supply)

Connection via M12: For IO-Link ports class B the supply of actuators is provided by an additional (galvanically isolated) power supply by AUX (auxiliary 24 V power) via Pin 2 (P24) and Pin 5 (N24).

Connection via clamps: If connected IO-Link Devices with IO-Link ports class B need a higher current consumption, additionally they can be supplied directly via the power supply.

Actuator supply (for IO-Link ports class B)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable

COM1 = 4.8 kBaud

COM2 = 38.4 kBaud

COM3 = 230.4 kBaud (optional according to Specification V1.0)

 

An IO-Link device supports only one of the defined data transmission rates.

According to Specification V1.1, the IO-Link master supports all data transmission rates and adapts itself automatically to the data transmission rate supported by the device.

IO-Link data rate
IO-Link specification

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Profile cable connection

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Article No.
BWU4077ASi module with integrated IO-Link master211out of AUXout of AUX2 x M12 cable sockets, straight, 5 poles1 mCOM1 / COM2 / COM3V1.1yes, depth: 35 mm1 x ASi, 1 x AUX1 ASi-5 address
BWU4748ASi module with integrated IO-Link master11-out of ASi-1 x M12 cable socket, straight, 5 poles1 mCOM1 / COM2 / COM3V1.1yes, depth: 35 mm1 x ASi1 ASi-5 address
BWU4088ASi module with integrated IO-Link master1-1out of AUXout of AUX1 x M12 cable socket, straight, 5 poles1 mCOM1 / COM2 / COM3V1.1yes, depth: 35 mm1 x ASi, 1 x AUX1 ASi-5 address

 

 

Active Distributors ASi-5, IP67, RGB Lights and RGB/RGBW Stripes

  • 2 x connectors for profile cable
  • round cable/connecting wires
  • M8 cable sockets, straight
Figure Inputs digital Outputs digital

inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential.

Input voltage (sensor supply)

Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.

 

For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet.

Output voltage (actuator supply)

PUR line, oil resistant. Further connection options are available on request.

      M12 socket M12 cable socket, angled  M12 cable socket, straight   M8 cable socket, straight   round cable/connecting wires     profile cable branch          push in terminals
       2 x round cables/connecting wires 2,5 mm²

Connection

Single wiring: 1 input or output per connection.

 

Y wiring: 2 inputs or outputs per connection.

 

Mixed wiring: 1 input and 1 output per connection.

 

Exact pin assignment see data sheet.

M8/M12 wiring

Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled.

In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted.

Round cable

Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation.

Flat design, installation in cable duct possible
Profile cable connection

AB address (max. 62 AB addresses/ASi network), 2 AB addresses (max. 31 modules with 2 AB addresses), Single addresses (max. 31 Single addresses/ASi network), ASi-5 address (max. 62 ASi-5 addresses/ASi network), mixed use allowed.
For ASi modules with two ASi nodes the second Asi node is turned off as long as the first Asi node is addressed to address "0".
Upon request, ASi modules are available with specific ASi node profiles.

ASi address
Special function Article No.
BWU4083-1 x RGB Light-out of AUX1 x M8 cable socket, straight, 4 poles-1 myes, depth: 35 mm1 x ASi, 1 x AUX1 ASi-5 address-
BWU4101-1 x RGB/RGBW LED Stripe-out of AUX1 x round cable/connecting wires-0,20 myes, depth: 35 mm1 x ASi, 1 x AUX1 ASi-5 address-