Active Distributors ASi Safety
Figure |
Type
|
ASi-5/ASi-3
|
Housing
|
Protection rating
|
Inputs Safety, SIL 3, Cat. 4
|
Inputs digital, EDM
|
Outputs digital
|
Safety signal inputs
|
Input voltage (sensor supply)
|
Output voltage (actuator supply)
|
Connection
|
Round cable
|
Flat design, installation in cable duct possible
|
LED status display
|
Profile cable connection
|
ASi connection
|
ASi address
|
Special function
|
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Active distributor ASi Safety | ASi-3 compatible | depth: 35 mm | IP67 | 1 x 2 channels | - | 1 x electronic | floating contacts | out of ASi | out of AUX | 1 x round cable/connecting wires | 1 m | yes, depth: 35 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 2 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight 8 poles + 1 x M12 cable socket, straight, 5 poles | 10 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Leuze MLC530SPG (operation mode 5) to ASi | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 1 x electronic | floating contacts | out of ASi | out of ASi | 2 x round cables/connecting wires | 1 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | - | floating contacts | out of ASi | - | 2 x round cables/connecting wires | 10 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 2 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | 2 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Leuze MLD530-RT3M (operation mode 5) to ASi | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 1 x electronic | floating contacts | out of ASi | out of ASi | 1 x round cable/connecting wires | 10 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 1 x electronic | floating contacts | out of ASi | out of ASi | 1 x round cable/connecting wires | 1 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | - | floating contacts | out of ASi | - | 1 x round cable/connecting wires | 0,30 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | - | floating contacts | out of ASi | - | 1 x M8 cable socket, straight, 4 poles | 0,20 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | to connect Sick RE13-SA84 / RE13-SAC / RE23-SAC / RE23-SA84 to ASi | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | - | floating contacts | out of ASi | - | 1 x M12 cable socket, angled, 5 poles | 1 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | - | floating contacts | out of ASi | - | 1 x M12 cable socket, straight, 5 poles | 1 m | yes, depth: 19 mm | yes | 1 x ASi | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 1 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, angled, 5 poles | 1 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 1 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight, 5 poles | 5 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | - | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | - | 1 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight, 5 poles | 1 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Euchner MGB / Sick STR1-SASMOAC5 to ASi | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | 1 | 1 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | 5 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Pilz PSENslock, PSENcode to ASi | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | 1 | 1 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | 1 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Pilz PSENslock, PSENcode to ASi | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | 1 | 1 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | 1 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Schmersal AZM400 to ASi | |
Active distributor ASi Safety | ASi-3 compatible | depth: 19 mm | IP67 | 1 x 2 channels | 1 | 1 x electronic | optoelectronic protective devices | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | 1 m | yes, depth: 19 mm | yes | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Schmersal AZM200 / AZM201 / AZM300 / MZM100 to ASi |