Logo Bihl+Wiedemann GmbH

Safety Monitor

Additional attributes:

    Figure
    Type
    ASi-5/ASi-3
    Model
    Protection rating
    Inputs Safety, SIL 3, Cat. 4
    Inputs digital, EDM
    Inputs safety, expandable to
    Outputs Safety, SIL 3, cat. 4
    Safety outputs, independent according to SIL 3, expandable to
    Safety communication
    Fieldbus interface
    Number of ASi networks, number of ASi Master
    Integrated decoupling coils, ASi current measurement in the gateway
    Diagnostic and configuration interface
    Recognition of duplicate ASi addresses
    ASi fault detector
    Programming in C
    Article No.
    Safety Basic Monitor
    ASi-3 compatible
    Safety Basic Monitor with extended features
    IP20
    4 x 2 channels, inputs 3+4, compatible as replacement with consortial monitor
    8
    max. 31 x 2 channels
    2 release circuits, 2 x electronic safe outputs
    max. 16
    -
    ASi monitors
    1 ASi network, no ASi Master, ASi Monitor
    no, max. 8 A/ASi network
    USB
    no
    no
    no
    Safety Basic Monitor
    ASi-3 compatible
    Safety Basic Monitor with extended features
    IP20
    4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
    8
    max. 31 x 2 channels
    2 release circuits, 2 x electronic safe outputs
    max. 16
    -
    ASi monitors
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply, no ASi current measurement
    USB
    no
    no
    no
    Safety Basic Monitor
    ASi-3 compatible
    Safety Basic Monitor with extended features
    IP20
    3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    2 release circuits, 2 x electronic safe outputs
    max. 32, max. 991 in max. configuration
    Safe Link
    ASi monitors
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply, no ASi current measurement
    Ethernet diagnostic + Modbus TCP diagnostic
    no
    no
    no
    Starter Kits
    ASi-3 compatible
    Safety Basic Monitor with extended features
    IP20
    4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)
    8
    max. 31 x 2 channels
    2 release circuits, 2 x electronic safe outputs
    max. 8
    -
    ASi monitors
    1 ASi network, 1 ASi-3 Master
    yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply, no ASi current measurement
    USB
    no
    no
    no
    Safety, PROFIBUS
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    PROFIBUS
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, PROFIBUS
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    PROFIBUS
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    PROFIsafe, PROFIBUS
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels
    6 release circuits, 6 x electronic safe outputs
    max. 31
    PROFIsafe (F-CPU) + ASIMON program
    PROFIBUS
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    PROFIsafe, PROFINET, ASi-5 / ASi-3
    ASi-5 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    PROFINET, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    PROFIsafe, PROFINET, ASi-5 / ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    PROFINET, OPC UA
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, PROFINET ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    Safe Link
    PROFINET, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, PROFINET ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    PROFINET, OPC UA
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    PROFIsafe, PROFINET, ASi-5 / ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    -
    -
    max. 31 x 2 channels, max. 1891 in max. configuration
    -
    max. 64, max. 1984 in max. configuration
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    PROFINET, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    -
    yes
    optional
    PROFIsafe, PROFINET, ASi-5 / ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    -
    -
    max. 31 x 2 channels, max. 1891 in max. configuration
    -
    max. 64, max. 1984 in max. configuration
    PROFIsafe (F-CPU) + ASIMON program + Safe Link
    PROFINET, OPC UA
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, PROFINET ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    -
    -
    max. 31 x 2 channels, max. 1891 in max. configuration
    -
    max. 64, max. 1984 in max. configuration
    Safe Link
    PROFINET, OPC UA
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, Sercos ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    safe Schneider drives over Sercos + Safe Link
    Sercos, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, Sercos ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    CIP Safety over Sercos + Safe Link
    Sercos, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, Sercos ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    -
    -
    max. 62 x 2 channels, max. 1922 in max. configuration
    -
    max. 64, max. 1984 in max. configuration
    CIP Safety over Sercos + Safe Link
    Sercos, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    CIP Safety over EtherNet/IP + Safe Link
    EtherNet/IP + ModbusTCP, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    Safe Link
    EtherNet/IP + ModbusTCP, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    EtherNet/IP + ModbusTCP, OPC UA
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, EtherNet/IP + ModbusTCP
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    EtherNet/IP + ModbusTCP
    2 ASi networks, 2 ASi-3 Masters
    no, max. 8 A/ASi network, redundant supply
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, BACnet/IP
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 128 x 2 channels, max. 3968 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 128, max. 3968 in max. configuration
    Safe Link
    BACnet/IP, OPC UA
    2 ASi networks, 2 ASi-3 Masters
    no, max. 8 A/ASi network, redundant supply
    Ethernet fieldbus + Ethernet diagnostic
    yes
    yes
    optional
    Safety, DeviceNet
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    DeviceNet
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, EtherCAT ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    FSoE + Safe Link
    EtherCAT, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, EtherCAT ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    FSoE + Safe Link
    EtherCAT, OPC UA
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, EtherCAT ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    Safe Link
    EtherCAT, OPC UA
    1 ASi network, 1 ASi-5/ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, POWERLINK ASi-5/ASi-3
    ASi-5 + ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 64, max. 1984 in max. configuration
    Safe Link
    POWERLINK, OPC UA
    2 ASi networks, 2 ASi-5/ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, POWERLINK
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 62 x 2 channels, max. 1922 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 32, max. 992 in max. configuration
    Safe Link
    POWERLINK
    2 ASi networks, 2 ASi-3 Masters
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, POWERLINK
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    POWERLINK
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, CANopen
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    CANopen
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional
    Safety, CC-Link
    ASi-3 compatible
    Gateway with integrated Safety Monitor
    IP20
    3 x 2 channels
    6
    max. 31 x 2 channels, max. 1891 in max. configuration
    6 release circuits, 6 x electronic safe outputs
    max. 31, max. 991 in max. configuration
    Safe Link
    CC-Link
    1 ASi network, 1 ASi-3 Master
    yes, max. 4 A/ASi network
    Ethernet diagnostic
    yes
    yes
    optional