Speed Monitors
BWU2852Safety Basic Monitor with extended features, 1 ASi master
Product description
Safety Basic Monitor with extended features, 1 ASi master, 1 power supply for 2 ASi networks, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), input 3 optional for speed monitors (up to 4kHz), expandable to max. 31 x 2 channels safe inputs, 1891 x 2 channels safe inputs in max. configuration, 2 release circuits (2 x electronic safe outputs), expandable to max. 32 safe outputs, 991 safe outputs in max. configuration, Safe Link, diagnostic and configuration via Ethernet or Modbus diagnostic interface, IP20
Safety compact controller with safety inputs and outputs.
Safety standstill/speed monitor for up to 3 axes.
Ethernet interface.
Technical data
Type | Safety Basic Monitor |
Model | Safety Basic Monitor with extended features |
Protection rating
"IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | IP20 |
Safe Monitoring | speed |
Encoder signal/Sensor signal | sensors/initiators (24V) |
Number of monitored axes | up to 2 independent axes |
Inputs Safety, SIL 3, Cat. 4 | 3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz) |
Outputs Safety, SIL 3, cat. 4 | 2 release circuits, 2 x electronic safe outputs |
Encoder/Sensor connection | clamps |
Diagnostic and configuration interface
"USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Ethernet diagnostic + Modbus TCP diagnostic |
ASi connection
The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| clamps |
ASi address
AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | - |
General information
Commissioning
Manuals
EPLAN Macros
Video Tutorial
- Video Tutorial: Tips & Tricks: Replacing a defective device (DE)
- Video Tutorial: Tips & Tricks: Replacing a defective device (EN)
- Video Tutorial: ASIMON360 configuration for Safety Basic Monitors (DE)
- Video Tutorial: ASIMON360 configuration for Safety Basic Monitors (EN)
- Video Tutorial: ASIMON360 configuration for Safe Link (DE)
- Video Tutorial: ASIMON360 configuration for Safe Link (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: Online bus information (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: Online bus information (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: Custom catalog (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: Custom catalog (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: How to copy slaves and devices (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: How to copy slaves and devices (EN)
- Video Tutorial: Tips & Tricks in ASIMON360: How to deactivate slaves (DE)
- Video Tutorial: Tips & Tricks in ASIMON360: How to deactivate slaves (EN)
Quick Start Guides
- Quick Start Guide: Tips & Tricks: Replacing a defective device (DE)
- Quick Start Guide: Tips & Tricks: Replacing a defective device (EN)
- Quick Start Guide: ASIMON360 configuration for Safety Basic Monitors (DE)
- Quick Start Guide: ASIMON360 configuration for Safety Basic Monitors (EN)
- Quick Start Guide: ASIMON360 configuration for Safe Link (DE)
- Quick Start Guide: ASIMON360 configuration for Safe Link (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: Custom catalog (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: Custom catalog (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to copy slaves and devices (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to copy slaves and devices (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to deactivate slaves (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: How to deactivate slaves (EN)
- Quick Start Guide: Tips & Tricks in ASIMON360: Online bus information (DE)
- Quick Start Guide: Tips & Tricks in ASIMON360: Online bus information (EN)
The product has earned the following certifications: