Power Supplies
Power Supplies
- ASi Power Supply
- 30 V Power Supply
- ASi Power Supply Decoupling Unit
- Power Decoupling Unit
Figure | "ASi power supply": Special power supplies with integrated data decoupling unit for use in ASi-3 only networks. Suitable for all Bihl+Wiedemann ASi-3 gateways and safety monitors. Inexpensive standard power supplies, suitable as an alternative for use with ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi gateways.
Inexpensive standard power supplies, optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated data decoupling unit (version "1 power supply , 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.
The 30 V/3 A power supply is UL certified, has power limitation <100 W and is designed for use in NEC class 2 networks. It is suitable for applications with 1 power supply per ASi network. In the case of power intensive applications, Bihl+Wiedemann recommends the use of a 30 V power supply without 100 W power limitation in combination with a power limitation module (BWU4189) for each ASi network.The power supply is optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated decoupling coils (version "1 power supplies, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 V ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.
Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling.
Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A. | Input voltage | Output current | Integrated in the power supply: Data decoupling is performed in the special ASi power supply with integrated data decoupling unit. ASi gateways and safety monitors missing their own, integrated data decoupling unit require a special ASi power supply for each ASi network. Integrated in the gateway: Bihl+Wiedemann ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") can be operated with an inexpensive 30 V standard power supply. | PUR line, oil resistant. Further connection options are available on request.
| "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | 30 V power supply, optimized for ASi-5/ASi-3, NEC class 2 | 100 ... 240 VAC, 1 phase | 3 A | integrated in the gateway | push in terminals | IP20 | BW422330 V Power Supply, 100 W, 1 phase | ||||||||||||||||||||
![]() | 30 V power supply, optimized for ASi-5/ASi-3 | 100 ... 240 VAC, 1 phase | 4 A | integrated in the gateway | push in terminals | IP20 | BW421830 V Power Supply, 4 A, 1 phase | ||||||||||||||||||||
![]() | 30 V power supply, optimized for ASi-5/ASi-3 | 100 ... 240 VAC, 1 phase | 8 A | integrated in the gateway | push in terminals | IP20 | BW421930 V Power Supply, 8 A, 1 phase | ||||||||||||||||||||
![]() | 30 V power supply, optimized for ASi-5/ASi-3 | 100 ... 240 VAC, 1 phase | 16 A | integrated in the gateway | push in terminals | IP20 | BW422130 V Power Supply, 16 A, 1 phase | ||||||||||||||||||||
![]() | 30 V power supply, optimized for ASi-5/ASi-3 | 400 ... 500 VAC, 3 phases | 8 A | integrated in the gateway | push in terminals | IP20 | BW422030 V Power Supply, 8 A, 3 phases | ||||||||||||||||||||
![]() | 30 V power supply, optimized for ASi-5/ASi-3 | 400 ... 500 VAC, 3 phases | 16 A | integrated in the gateway | push in terminals | IP20 | BW422230 V Power Supply, 16 A, 3 phases | ||||||||||||||||||||
![]() | ASi power supply | 90 ... 265 VAC, wide range supply | 4 A | integrated in the power supply | push in terminals | IP20 | BW1649ASi Power Supply, 4 A | ||||||||||||||||||||
![]() | ASi power supply | 115 ... 250 VAC | 1,8 A | integrated in the power supply | push in terminals | IP20 | BW2255ASi Power Supply 1,8 A | ||||||||||||||||||||
![]() | ASi power supply | 115 VAC / 230 VAC, power supply with range switch | 8 A | integrated in the power supply | push in terminals | IP20 | BW1997ASi Power Supply, 8 A | ||||||||||||||||||||
![]() | ASi power supply | 195 ... 500 VAC, wide range supply | 8 A | integrated in the power supply | push in terminals | IP20 | BW2276ASi Power Supply, 8 A | ||||||||||||||||||||
![]() | ASi power supply | 24 VDC to 30 VDC ASi output voltage | 2 A | integrated in the power supply | push in terminals | IP20 | BW1760ASi Power Supply, 2A | ||||||||||||||||||||
![]() | ASi power supply decoupling unit | - | 4 A | - | push in terminals | IP20 | BWU1943ASi Power Supply Decoupling Unit, 4 A | ||||||||||||||||||||
![]() | ASi power supply decoupling unit | - | 4 A | - | 3 x PG cable connectors | IP65 | BWU1477ASi Power Supply Decoupling Unit, 4 A | ||||||||||||||||||||
![]() | Power decoupling unit | - | 1,2 A | - | push in terminals | IP20 | BWU2387ASi Module for Power Decoupling, 1,2 A | ||||||||||||||||||||
![]() | Power limiting module | 18 … 33 VDC | ≤ 3 A per output | - | - | IP20 | BWU41892 channel Power Limiting Module, limited energy circuit (< 100 W), IP20 |
Voltage converter 48 V/24 V
Figure | "ASi power supply": Special power supplies with integrated data decoupling unit for use in ASi-3 only networks. Suitable for all Bihl+Wiedemann ASi-3 gateways and safety monitors. Inexpensive standard power supplies, suitable as an alternative for use with ASi gateways and safety monitors with integrated data decoupling unit (version "1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi gateways.
Inexpensive standard power supplies, optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated data decoupling unit (version "1 power supply , 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 Volt ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.
The 30 V/3 A power supply is UL certified, has power limitation <100 W and is designed for use in NEC class 2 networks. It is suitable for applications with 1 power supply per ASi network. In the case of power intensive applications, Bihl+Wiedemann recommends the use of a 30 V power supply without 100 W power limitation in combination with a power limitation module (BWU4189) for each ASi network.The power supply is optimized for use with ASi-5/ASi-3 gateways and safety monitors with integrated decoupling coils (version "1 power supplies, 1 gateway for 2 ASi networks, inexpensive power supplies") and with all 24 V ASi-5/ASi-3 gateways. In order to avoid interferences in ASi-5 communication, Bihl+Wiedemann recommends the use of power supplies optimized for ASi-5/ASi-3.
Supply of 2 ASi networks out of 1 power supply. Applicable with double masters without integrated data decoupling.
Take up to 1,2 A out of ASi. In combination with an ASi Repeater: decouples 1,2 A from ASi Segment B and supplies Segment A with 1,2 A. | Input voltage | Output voltage | Output current | Profile cable connection | PUR line, oil resistant. Further connection options are available on request.
| Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled. In the case of the active distributors (ASi modules) however only the one ASi profile cable is counted. | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Voltage converter 48 V/24 V | ASi + 48 VDC (AUX) | ASi + 24 VDC (AUX) | 1 A | 1 x ASi, 1 x AUX 48 V | 1 x M12 cable socket, angled, 5 poles | 1 m | IP67 | BWU4249Voltage converter 48 V/24 V, 1 A, ASi/AUX 48 V profile cables to 1 x M12 cable socket, angled, 5 poles (ASi/AUX 24 V), 35 mm, IP67 | ||||||||||||||||||||
![]() | Voltage converter 48 V/24 V | 48 VDC (AUX) | 24 VDC (AUX) | 1 A | 1 x AUX 48 V | 1 x M12 cable socket, angled, 5 poles | 1 m | IP67 | BWU4250Voltage converter 48 V/24 V, 1 A, AUX 48 V profile cable to 1 x M12 cable socket, angled, 5 poles (AUX 24 V), 35 mm, IP67 | ||||||||||||||||||||
![]() | Voltage converter 48 V/24 V | 48 VDC (AUX) | 24 VDC (AUX) | 1 A | 1 x AUX 24 V, 1 x AUX 48 V | profile cable branch | - | IP67 | BWU4248Voltage converter 48 V/24 V, 1 A, AUX 48 V profile cable to AUX 24 V profile cable, 35 mm, IP67 |