Safety Monitor
The Safety Monitor enables safe transmission and processing of safety relevant data from safety input slaves and safe shut-off of safety output slaves remotely over ASi right where the potentially hazardous motion takes place. And always PLe compliant.
Bihl+Wiedemann offers the Safety Monitor for ASi Safety at Work as a stand-alone device for expanding existing ASi circuits with safety slaves. For new systems we can provide our ASi-3 resp. ASi-5/ASi-3 gateways with integrated Safety Monitor and interfaces for the most commonly used automation systems using the most efficient method for safely constructing 1 or 2 ASi circuits at the same time. Even large applications with up to 1922 safety I/Os can be implemented with these devices using our “Safe Link over Ethernet” technology by connecting multiple gateways safely over Ethernet/Profinet.
For small applications with three or more safe signals you should consider our Safety Basic Monitor, a compact safety controller without gateway but with configurable status outputs. The module allows for universal expansion and is also ideal as a head station for special safety applications.
Safety Basic Monitors
- Safety controllers, compact safety controller, programmable safety components
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety Basic Monitor | Safety Basic Monitor with extended features | IP20 | 3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz) | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 2 release circuits, 2 x electronic safe outputs | max. 32, max. 991 in max. configuration | Safe Link | Signaling contacts | 1 ASi network, 1 ASi Master | yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply | Ethernet diagnostic + Modbus TCP diagnostic | no | no | no | BWU2852Safety Basic Monitor with extended features, 1 ASi master |
![]() | Safety Basic Monitor | Safety Basic Monitor with extended features | IP20 | 4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz) | 8 | max. 31 x 2 channels | 2 release circuits, 2 x electronic safe outputs | max. 16 | - | Signaling contacts | 1 ASi network, 1 ASi Master | yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply | USB | no | no | no | BWU2700Safety Basic Monitor with extended features, 1 ASi master |
![]() | Safety Basic Monitor | Safety Basic Monitor with extended features | IP20 | 4 x 2 channels, inputs 3+4, compatible as replacement with consortial monitor | 8 | max. 31 x 2 channels | 2 release circuits, 2 x electronic safe outputs | max. 16 | - | ASi monitors | 1 ASi network, 1 ASi Master | no, max. 8 A/ASi network | USB | no | no | no | BWU2567Safety Basic Monitor with extended features, 1 ASi master |
![]() | Starter Kits | Safety Basic Monitor with extended features | IP20 | 4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz) | 8 | max. 31 x 2 channels | 2 release circuits, 2 x electronic safe outputs | max. 8 | - | Signaling contacts | 1 ASi network, 1 ASi Master | yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply | USB | no | no | no | BW2512Safety Basic Monitor Starter Kit |
Safety, PROFINET
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large systems
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | PROFIsafe, PROFINET, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3674ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | PROFIsafe, PROFINET, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3862ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() | Safety, PROFINET ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU4000ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, PROFINET ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3863ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() | PROFIsafe, PROFINET, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | - | - | max. 31 x 2 channels, max. 1891 in max. configuration | - | max. 64, max. 1984 in max. configuration | PROFIsafe (F-CPU) + ASIMON program + Safe Link | PROFINET, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | - | yes | optional | BWU3833ASi-5/ASi-3 PROFIsafe via PROFINET Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 master |
![]() | Safety, PROFINET ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | - | - | max. 31 x 2 channels, max. 1891 in max. configuration | - | max. 64, max. 1984 in max. configuration | Safe Link | PROFINET, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3998ASi-5/ASi-3 PROFINET Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
Safety, EtherNet/IP + ModbusTCP
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large systems
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | CIP Safety over EtherNet/IP + Safe Link | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3857ASi-5/ASi-3 CIP Safety over EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | EtherNet/IP + ModbusTCP, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3825ASi-5/ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | EtherNet/IP + ModbusTCP, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3866ASi-5/ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
![]() | Safety, EtherNet/IP + ModbusTCP | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | EtherNet/IP + ModbusTCP | 2 ASi networks, 2 ASi Masters | no, max. 8 A/ASi network, redundant supply | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU3544ASi-3 EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi masters |
Safety, EtherCAT
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large systems
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, EtherCAT ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | FSoE + Safe Link | EtherCAT, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU3858ASi-5/ASi-3 Safety over EtherCAT Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, EtherCAT ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | Safe Link | EtherCAT, OPC UA | 1 ASi network, 1 ASi-5/ASi-3 Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU3991ASi-5/ASi-3 EtherCAT Gateway with integrated Safety Monitor, 1 ASi-5/ASi-3 master |
Safety, POWERLINK
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large applications
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, POWERLINK | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | POWERLINK | 2 ASi networks, 2 ASi Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU3176ASi-3 POWERLINK Gateway with integrated Safety Monitor, 2 ASi masters |
![]() | Safety, POWERLINK | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | POWERLINK | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU3177ASi-3 POWERLINK Gateway with integrated Safety Monitor, 1 ASi master |
Safety, Sercos
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large systems
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, Sercos ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | safe Schneider drives over Sercos + Safe Link | Sercos, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU3861ASi-5/ASi-3 safe Schneider drives over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, Sercos ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 64, max. 1984 in max. configuration | CIP Safety over Sercos + Safe Link | Sercos, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU3860ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
![]() | Safety, Sercos ASi-5/ASi-3 | Gateway with integrated Safety Monitor | IP20 | - | - | max. 62 x 2 channels, max. 1922 in max. configuration | - | max. 64, max. 1984 in max. configuration | CIP Safety over Sercos + Safe Link | Sercos, OPC UA | 2 ASi networks, 2 ASi-5/ASi-3 Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU3845ASi-5/ASi-3 CIP Safety over Sercos Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters |
Safety, PROFIBUS
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large applications
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | PROFIsafe, PROFIBUS | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels | 6 release circuits, 6 x electronic safe outputs | max. 31 | PROFIsafe (F-CPU) + ASIMON program | PROFIBUS | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU2819ASi-3 PROFIsafe via PROFIBUS Gateway with integrated Safety Monitor, 1 ASi master |
![]() | Safety, PROFIBUS | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | PROFIBUS | 2 ASi networks, 2 ASi Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU2822ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 2 ASi masters |
![]() | Safety, PROFIBUS | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | PROFIBUS | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU2793ASi-3 PROFIBUS Gateway with integrated Safety Monitor, 1 ASi master |
Safety, BACnet/IP
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large applications
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, BACnet/IP | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 128 x 2 channels, max. 3968 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 128, max. 3968 in max. configuration | Safe Link | BACnet/IP, OPC UA | 2 ASi networks, 2 ASi Masters | no, max. 8 A/ASi network, redundant supply | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BWU4001ASi-3 BACnet/IP Gateway with integrated Safety Monitor, 2 ASi masters |
Safety, DeviceNet
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, DeviceNet | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | DeviceNet | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU2972ASi-3 DeviceNet Gateway with integrated Safety Monitor, 1 ASi master |
Safety, CANopen
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, CANopen | Gateway with integrated Safety Monitor | IP20 | CANopen | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU2804ASi-3 CANopen Gateway with integrated Safety Monitor, 1 ASi master |
Safety, CC-Link
- Safety diagnostics in real-time
- Cost-optimized solution for medium-size and large systems
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Safety, CC-Link | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | CC-Link | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BWU2833ASi-3 CC-Link Gateway with integrated Safety Monitor, 1 ASi master |
Starter Kits
- Fully assembled and wired in a practical case
Figure | Type | Model | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs Safety, SIL 3, Cat. 4 | An externally connected relay (contactor) can be connected via a feedback loop to the Safety Monitor for monitoring purposes. | Inputs safety, expandable to | Outputs Safety, SIL 3, cat. 4 | Safety outputs, independent according to SIL 3, expandable to | Safety communication |
Communication interface between fieldbus and gateway: interfaces for standardized fieldbus systems in industrial automation. PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus
PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane POWERLINK ASi gateway: interface for an POWERLINK fieldbus OPC UA server: interface for the OPC UA communication
| Standard devices"Single Master": 1 ASi network, 1 ASi Master. 2 ASi networks, 2 ASi Masters. Safety devices "Single Master" : | " yes, max. 4 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible. " yes, max. 8 A/ASi network ": Operation with short cable lengths with standard 24 V power supply possible.
Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate. 1 ASi power supply per ASi network. | "USB": Access to ASi Master and Safety Monitor with Bihl+Wiedemann proprietary software by using the USB interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface or Ethernet fieldbus interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet diagnostic interface. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software or via Modbus TCP by using the Ethernet diagnostic interface. For a full-fledged Modbus TCP fieldbus interface use one of our Modbus TCP gateways in stainless steel or Modbus TCP gateways with integrated safety monitor. Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using the Ethernet fieldbus interface or by using an adapter cable via RS 232 interface.
Access to ASi Master and Safety Monitor with Bihl+Wiedemann software by using an adapter cable via RS 232 interface. The latest version of the device description file of the gateway/gateway with integrated safety monitor (GSD, GSDML, EDS, etc.) is available in the "Downloads" section of the respective device. | Detects whether the same address has been assigned to two ASi slaves. Frequent error when using a handheld addressing device. | Checks the ASi line for interference effects such as noise, external voltages, ... | Using a C-program offers the possibility to run mini-PLC functions with a gateway. | Article No. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Starter Kits | Safety Basic Monitor with extended features | IP20 | 4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz) | 8 | max. 31 x 2 channels | 2 release circuits, 2 x electronic safe outputs | max. 8 | - | Signaling contacts | 1 ASi network, 1 ASi Master | yes, max. 0,5 A/ASi network, max. 8 A with ASi power supply | USB | no | no | no | BW2512Safety Basic Monitor Starter Kit |
![]() | Starter Kits | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 62 x 2 channels, max. 1922 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | PROFINET | 2 ASi networks, 2 ASi Masters | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BW3000Small Starter Kit Safe Link |
![]() | Starter Kits | Gateway with integrated Safety Monitor | IP20 | 3 x 2 channels | 6 | max. 31 x 2 channels, max. 1891 in max. configuration | 6 release circuits, 6 x electronic safe outputs | max. 31, max. 991 in max. configuration | Safe Link | PROFINET | 1 ASi network, 1 ASi Master | yes, max. 4 A/ASi network | Ethernet fieldbus + Ethernet diagnostic | yes | yes | optional | BW3074Small Starter Kit Safety Gateway in Stainless Steel |
![]() | Starter Kits | Gateway with integrated Safety Monitor | IP20 | - | 4 | max. 62 x 2 channels, max. 1922 in max. configuration | 4 release circuits, 2 x relay, 2 x electronic safe outputs | max. 32, max. 992 in max. configuration | Safe Link | PROFIBUS | 2 ASi networks, 2 ASi Masters | yes, max. 4 A/ASi network | Ethernet diagnostic | yes | yes | optional | BW2695Safety Gateways in Stainless Steel Starter Kit |