I/O Modules
Bihl+Wiedemann offers a wide variety of ASi modules, all of which are compatible with the current ASi-3 resp. ASi-5 standard. These are equipped with a various number of in- and outputs offering the right module for any application. Nor are special requirements a problem, such as sensors powered from ASi or external voltage (AUX). The large selection of analog modules reflects the commitment to offering the right module for any application or analog signal. Deserving special mention are high-resolution 16-bit analog modules or modules for especially fast transmission of the analog values.
EXTREME product line for ASi: Digital Modules ASi, IP67, M12
- 100% protection against moisture
- High resistance to salt spray
- High corrosion resistance to chemically active substances
- Assured functionality at extreme temperatures from – 40 °C to 70 °C
- Shock resistant to 30g (11 ms)
- Vibration rated for a frequency of 5...500 Hz at an amplitude of 50 mmpp / 6g
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs digital | Outputs digital | either as a single–wiring, Y–wiring or mixed-wiring.
| inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP67, 4 x M12, EXTREME | 4 x M12 | IP67 | 4 | - | Y | out of ASi | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3145ASi Digital Input Module EXTREME, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, EXTREME | 8 x M12 | IP67 | 4 | 4 x electronic | Y | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3144ASi Digital I/O Module EXTREME, IP67, M12, 4I/4O |
Digital Modules ASi, IP67, M12
- IP67, M12: 2 x 2 connectors for profile cable
- 2 color LEDs per output, state yellow, overload red (optional)
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs digital | Outputs digital | Inputs analog | either as a single–wiring, Y–wiring or mixed-wiring.
| inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP67, 4 x M12, EXTREME | 4 x M12 | IP67 | 4 | - | - | Y | out of ASi | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3145ASi Digital Input Module EXTREME, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 | 2 x electronic | - | Y | out of ASi | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3456ASi Digital I/O Module, IP67, M12, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 | 2 x electronic, special ASi bit assignment | - | Y | out of ASi | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3539ASi Digital I/O Module, IP67, M12, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 | 2 x electronic, special ASi bit assignment | - | Y | out of ASi | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU3775ASi Digital I/O Module, IP67, M12, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 | 2 x electronic | - | Single | out of ASi | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3141ASi Digital I/O Module, IP67, M12, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 | 2 x electronic | - | Single | out of ASi | out of AUX | 4 x M12 sockets, 5 poles | ASi via M12 | 1 AB Slave | BWU3517ASi Digital I/O Module, IP67, M12, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | - | - | Y | out of ASi | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2552ASi Digital Input Module, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | - | - | Y | out of ASi | - | 4 x M12 sockets, 5 poles | ASi via M12 | 1 AB Slave | BWU3077ASi Digital Input Module, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | - | - | Single | out of ASi | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2620ASi Digital Input Module, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | - | - | Single | out of ASi | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave S-0.A.7.0 | BWU3556ASi Digital Input Module, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | - | - | Single | out of ASi | - | 4 x M12 sockets, 5 poles | ASi via M12 | 1 AB Slave | BWU3457ASi Digital Input Module, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | - | - | Single | out of AUX | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2725ASi Digital Input Module, IP67, M12, 4I | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | 2 x electronic | - | Mixed | out of AUX | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2767ASi Motor Module, IP67, M12, 4I/2O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | 3 x electronic | - | Y | out of ASi | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3375ASi Digital I/O Module, IP67, M12, 4I/3O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | 4 x electronic | - | Y | out of ASi | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2487ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | 4 x electronic | - | Y | out of AUX | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3032ASi Motor Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | 4 x electronic | - | Mixed (inputs/outputs swapped) | out of AUX | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3887ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | 4 x electronic | - | Mixed | out of AUX | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2547ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 4 | 4 x electronic | - | Mixed | out of ASi | out of ASi | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3240ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | - | 4 x electronic | - | Y | - | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU2713ASi Digital Output Module, IP67, M12, 4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | - | 4 x electronic | - | Y | - | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2594ASi Digital Output Module, IP67, M12, 4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | - | 4 x electronic | - | Y | - | out of AUX, 2 A per output | 4 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2728ASi Digital Output Module, IP67, M12, 4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | up to 16, depending on configuration | up to 16 x electronic, depending on configuration | - | Y/mixed, depending on configuration | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU4230ASi-5 Self-configuring I/O Module, IP67, M12, 16I/O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | up to 16, depending on configuration | up to 16 x electronic, depending on configuration | - | Y/mixed, depending on configuration | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU4231ASi-5 Self-configuring I/O Module, IP67, M12, 16I/O | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12, ASi-5 | 4 x M12 | IP67 | bis zu 8, abhängig von der Konfiguration | up to 8 x electronic, depending on configuration | - | Y/mixed, depending on configuration | out of AUX | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU4232ASi-5 Self-configuring I/O Module, IP67, M12, 8I/O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 8 | - | - | Single | out of ASi | - | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU3802ASi-5 Digital Input Module, IP67, M12, 8I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 8 | - | - | Single | out of ASi | - | 8 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU4195ASi-5 Digital Input Module, IP67, M12, 8I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 8 | - | - | Single | out of AUX | - | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU3893ASi-5 Digital Input Module, IP67, M12, 8I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 8 | 8 x electronic | - | Y | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU3163ASi-5 Digital I/O Module, IP67, M12, 8I/8O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 8 | 8 x electronic | - | Y | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU4193ASi-5 Digital I/O Module, IP67, M12, 8I/8O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 8 | 8 x electronic | - | Y | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU4207ASi-5 Digital I/O Module, IP67, M12, 8I/8O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 16 | - | - | Y | out of ASi | - | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU3164ASi-5 Digital Input Module, IP67, M12, 16I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 16 | - | - | Y | out of ASi | - | 8 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU4194ASi-5 Digital I/O Module, IP67, M12, 16I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 16 | - | - | Y | out of AUX | - | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU3890ASi-5 Digital Input Module, IP67, M12, 16I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | 16 | - | - | Y | out of AUX | - | 8 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU4196ASi-5 Digital I/O Module, IP67, M12, 16I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, ASi-5 | 8 x M12 | IP67 | - | 8 x electronic | - | Single | - | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU3894ASi-5 Digital Output Module, IP67, M12, 8O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12, EXTREME | 8 x M12 | IP67 | 4 | 4 x electronic | - | Y | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3144ASi Digital I/O Module EXTREME, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Y | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3510ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Y | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2626ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Y | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3426ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Single | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2617ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Single | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU2684ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Single | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU2810ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Single | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi via M12 | 1 AB Slave | BWU2645ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | - | Single | out of ASi | out of AUX, 2 A per output | 8 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU3540ASi Digital I/O Module, IP67, M12, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 3 x electronic | - | Single | out of ASi | out of AUX, 2 A per output | 8 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3496ASi Digital I/O Module, IP67, M12, 4I/3O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 8 | - | - | Y | out of AUX | - | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU2770ASi Digital Input Module, IP67, M12, 8I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 8 | - | - | Y | out of ASi | - | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU2651ASi Digital Input Module, IP67, M12, 8I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 8 | - | - | Single | out of ASi | - | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU2983ASi Digital Input Module, IP67, M12, 8I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 8 | 8 x electronic | - | Y | out of ASi | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU2619ASi Digital I/O Module, IP67, M12, 8I/8O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 8 | 8 x electronic | - | Y | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU3892ASi Digital I/O Module, IP67, M12, 8I/8O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | - | 8 x electronic | - | Y | - | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU2652ASi Digital Output Module, IP67, M12, 8O | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 4 | 4 x electronic | 2 x Pt100 | Signal at pin2/pin4 | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU2313ASi Analog Input Module, IP67, M12, 2AI (Pt100)/4I/4O |
An AS-Interface installation with IP67 digital modules from Bihl+Wiedemann having M12 plug-in connections offers many advantages: There are 2 x 2 connections for the yellow profile cable in the substructure of the module. These enable an clearly organized ASi installation where up to 4 ASi end caps and 2 passive distributors per module can be saved.
![]() | ![]() | ||||||||
(Click to enlarge): ASi Installation with modules from Bihl+Wiedemann | (Click to enlarge): ASi Installation with traditional modules |
ASi Slaves/IO-Link Masters: IP67, M12
- IO-Link ports class A
- IO-Link ports class B
- IP67, M12: 2 x 2 connectors for profile cable
Figure | Type | Model | Number of IO-Link Ports | Port class A (M12): Pin 4 configurable (IO-Link/DI/DO), additional digital input at pin 2. Compatible with 3 pol IO-Link devices (M8). Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8). | Port class B (M12): Pin 4 configurable (IO-Link/DI/DO), additional power supply (galvanically isolated) for IO-Link devices at pins 2 and 5. Compatible with 3 pol IO-Link devices (M8). Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8). | IO-Link and additional inputs/outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs can neither be connected to earth nor to external potential. | Connection via M12: For IO-Link ports class B the supply of actuators is provided by an additional (galvanically isolated) power supply by AUX (auxiliary 24 V power) via Pin 2 (P24) and Pin 5 (N24). Connection via clamps: If connected IO-Link slaves with IO-Link ports class B need a higher current consumption, additionally they can be supplied directly via the power supply. | COM1 = 4.8 kBaud COM2 = 38.4 kBaud COM3 = 230.4 kBaud (optional according to Specification V1.0)
An IO-Link device supports only one of the defined data transmission rates. According to Specification V1.1, the IO-Link master supports all data transmission rates and adapts itself automatically to the data transmission rate supported by the device. | IO-Link specification | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP67, 4 x M12, ASi-5 | ASi slave/IO-Link master | 4 | 2 | 2 | out of AUX | out of AUX | COM1 / COM2 / COM3 | V1.1 | 4 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU4067ASi-5 Slave/IO-Link Master with 4 Ports, IP67, M12, 2 IO-Link Ports Class A/2 IO-Link Ports Class B | ||||||||||||||||||||
![]() | IP67, 4 x M12, ASi-5 | ASi slave/IO-Link master | 4 | 2 | 2 | out of AUX | out of AUX | COM1 / COM2 / COM3 | V1.1 | 4 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU3897ASi-5 Slave/IO-Link Master with 4 Ports, IP67, M12, 2 IO-Link ports class A/2 IO-Link ports class B | ||||||||||||||||||||
![]() | IP67, 4 x M12, ASi-5 | ASi slave/IO-Link master | 4 | 4 | - | out of AUX | - | COM1 / COM2 / COM3 | V1.1 | 4 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU3819ASi-5 Slave/IO-Link Master with 4 Ports, IP67, M12, 4 IO-Link ports class A | ||||||||||||||||||||
![]() | IP67, 4 x M12, ASi-5 | ASi slave/IO-Link master | 4 | 4 | - | out of AUX | - | COM1 / COM2 / COM3 | V1.1 | 4 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU3899ASi-5 Slave/IO-Link Master with 4 Ports, IP67, M12, 4 IO-Link ports class A | ||||||||||||||||||||
![]() | Starter Kits | Gateway | 4 | 2 | 2 | out of AUX | out of AUX | COM1 / COM2 / COM3 | V1.1 | 4 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BW4211Small Starter Kit ASi-5/IO-Link | ||||||||||||||||||||
![]() | Starter Kits | Gateway | 4 | 2 | 2 | out of AUX | out of AUX | COM1 / COM2 / COM3 | V1.1 | 4 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BW4229Small Starter Kit ASi-5/IO-Link |
Digitalmodule ASi: IP67, M8
- IP67, M8: 2 x 2 connectors for profile cable
- 2color LEDs per output, state yellow, overload red (optional)
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs digital | Outputs digital | either as a single–wiring, Y–wiring or mixed-wiring.
| inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP67, 8 x M8 | 8 x M8 | IP67 | 8 | - | Single | out of ASi | - | 8 x M8 sockets, 3 poles | ASi profile cable | 2 AB Slaves | BW3521ASi Digital Input Module, IP67, M8, 8I | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M8 | 8 x M8 | IP67 | 4 | 4 x electronic | Single | out of ASi | out of AUX | 8 x M8 sockets, 3 poles | ASi profile cable | 1 AB Slave | BW3661ASi Digital I/O Module, IP67, M8, 4I/4O |
ASi Counter Modules, IP67, M12
- Conter input 4 x 2 channels or 4 x 1 channel, depending on configuration
- Pulse counter
- IP67, M12: 2 x 2 connectors for profile cable
Figure | Type | Model | Inputs digital | Range of value | counting rate | either as a single–wiring, Y–wiring or mixed-wiring.
| inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP67, 4 x M12, ASi-5 | counter module, pulse counter | 4 x counter inputs | -32768 ... 32767 dec. | max. 250 kHz | Pin2 = Pulse | out of ASi | 4 x M12 sockets, 5 poles | ASi profile cable | 1 ASi-5 Slave | BWU4042ASi-5 Counter Module, IP67, M12 | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12, ASi-5 | counter module, pulse counter | 4 x counter inputs | -32768 ... 32767 dec. | max. 250 kHz | Pin2 = Pulse | out of ASi | 4 x M12 sockets, 5 poles | ASi via M12 | 1 ASi-5 Slave | BWU4202ASi-5 Counter Module, IP67, M12 |
Digital Modules ASi: Active Distributors ASi, IP67/IP20
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs digital | Outputs digital | Inputs Safety, SIL 3, Cat. 4 | inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| either as a single–wiring, Y–wiring or mixed-wiring.
| Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled. In the case of the active distributors (ASi slaves) however only the one ASi profile cable is counted. | Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation. | Profile cable connection | The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Special function | Article No. | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Active distributor ASi | depth: 35 mm | IP54 | 4 | 4 x electronic | - | out of ASi | out of AUX | 8 x M12 cable sockets, straight, 5 poles + 1 x ASi addressing cable socket | Single | I1/O4: 0,35 m, I2/O3: 0,25 m, I3/O2: 0,15 m, I4/O1: 0,05 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3675Active Distributor ASi, IP54, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP54 | 4 | 4 x electronic | - | out of AUX | out of AUX | 3 x M12 cable sockets, straight, 5 poles + 2 x M8 snap-in cable sockets, straight, 4 poles + 1 x ASi addressing cable socket | - | I1/I2: 0,1 m, I3/I4: 0,3 m, O1/O2: 0,2 m, O3/O4: 0,3 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3676Active Distributor ASi, IP54, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 2 x electronic | - | out of ASi | out of ASi | 6 x M8 cable sockets, straight, 4 poles | - | I: 0,15 m, O: 0,50 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | optimized to control valves Festo CPE14 / VUVG-L14 via ASi | BWU3577Active Distributor ASi, IP67, 4I/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of ASi | out of AUX | 4 x M8 cable sockets, straight, 4 poles | Y | 0,20 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3555Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 2 | 2 x electronic | - | out of ASi | out of ASi | 2 x M12 cable sockets, straight, 5 poles + 2 x M8 cable socket, straight, 3 poles | Single | I: 0,20 m, O: 0,40 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3695Active Distributor ASi, IP67, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | - | - | out of ASi | - | 4 x M12 cable sockets, straight, 5 poles | Single | 2 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3633Active Distributor ASi, IP67, 4I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | - | - | out of ASi | - | 4 x M12 cable sockets, straight, 5 poles | Single | 0,30 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3632Active Distributor ASi, IP67, 4I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP54 | 4 | - | - | out of ASi | - | 4 x M12 cable socket, straight, 5 poles + 1 x ASi addressing cable socket | Single | I1: 0,35 m, I2: 0,25 m, I3: 0,15 m, I4: 0,05 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3730Active Distributor ASi, IP54, 4I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | - | - | out of AUX | - | 3 x round cable/connecting wires + 1 x M8 cable socket, straight, 4 poles | - | 1 m | yes, depth: 35 mm | - | ASi profile cable | 1 AB Slave | - | BWU3608Active Distributor ASi, IP67, 4I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of ASi | out of AUX | 4 x round cable/connecting wires | - | 1 m | yes, depth: 35 mm | profile cable, piercing | ASi profile cable | 1 AB Slave | - | BWU4172Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of ASi | out of AUX | 2 x round cables/connecting wires | - | 1 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3317Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of ASi | out of AUX | 2 x M12 cable sockets, straight, 5 poles | - | 1 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BW3507Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of ASi | out of ASi | 2 x round cables/connecting wires | - | 1 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3326Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 3 | 4 x electronic | - | out of AUX | out of AUX | 2 x M12 cable sockets, straight, 5 poles | - | X1: 0,25 m, X2: 2 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | to connect K50Pro Banner Stacklight to ASi | BWU3785Active Distributor ASi, IP67, 3I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | - | - | out of ASi | - | 2 x round cables/connecting wires | - | 0,50 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3374Active Distributor ASi, IP67, 4I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 1 | 4 x electronic | - | out of ASi | out of ASi | 1 x M12 cable socket, straight, 5 poles + 1 x M12 cable socket, angled, 5 poles | - | 0,30 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | to connect Banner K50 Series EZ-Light, type K50L...PQ + Wenglor light curtains Pick-to-Light | BWU3534Active Distributor ASi, IP67, 1I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP54 | - | 4 x electronic | - | - | out of ASi | 1 x round cable/connecting wires + 1 x ASi addressing cable socket | - | 4 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3729Active Distributor ASi, IP54, 4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of ASi | out of ASi | 1 x round cable/connecting wires | - | 5 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BW3500Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of ASi | out of ASi | 1 x round cable/connecting wires | - | 2 m | yes, depth: 35 mm | - | ASi profile cable | 1 AB Slave | to connect Stack-Light Banner TL50GYRAQ + audible alarm (180 mA) to ASi | BWU3606Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 4 | 4 x electronic | - | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | - | 1 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | to connect Euchner MGB to ASi | BW3377Active Distributor ASi, IP67, 4I/4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 2 | 2 x electronic | - | out of AUX | out of AUX | 1 x round cable/connecting wires | - | 3 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | to control Linak LA12 drives | BWU3607Active Distributor ASi, IP67, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 35 mm | IP67 | 1 | 3 x electronic | - | out of ASi | out of ASi | 1 x M12 cable socket, angled, 8 poles | - | 0,30 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 AB Slave | to connect Banner K50 Series EZ-LIGHT, Typ K50AP...F2Q to ASi | BWU3639Active Distributor ASi, IP67, 1I/3O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 4 | - | - | out of AUX | - | 2 x M12 cable sockets, straight, 5 poles | Y | 0,40 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3498Active Distributor ASi, IP67, 4I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 2 | 2 x electronic | - | out of AUX | out of AUX | 1 x round cable/connecting wires + 1 x M12 cable sockets, straight, 5 poles | Y | I: 0,4 m, O: 1,5 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3628Active Distributor ASi, IP67, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 2 | 2 x electronic | - | out of AUX | out of AUX | 2 x M12 cable sockets, straight, 5 poles | Y | 0,40 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3497Active Distributor ASi, IP67, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 2 | 2 x electronic | - | out of AUX | out of AUX | 2 x round cables/connecting wires | - | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3602Active Distributor ASi, IP67, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 2 | 1 x electronic | - | out of AUX | out of AUX | 2 x M12 cable sockets, angled, 5 poles | 1 x Y + 1 x Mixed | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BW3250Active Distributor ASi, IP67, 2I/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 2 | 2 x electronic | - | out of ASi | out of ASi | 1 x M12 cable socket, straight, 8 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3400Active Distributor ASi, IP67, 2I/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 2 | - | - | out of ASi | - | 1 x M12 cable socket, angled, 5 poles | Y | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 AB Slave | - | BWU3642Active Distributor ASi, IP67, 2I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | 2 | - | - | out of AUX | - | 1 x M12 cable socket, angled, 5 poles | Y | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3564Active Distributor ASi, IP67, 2I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | - | 4 x electronic | - | - | out of AUX | 1 x round cable/connecting wires | - | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BW3300Active Distributor ASi, IP67, 4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | - | 4 x electronic | - | - | out of AUX | 1 x round cable/connecting wires | - | 5 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3487Active Distributor ASi, IP67, 4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP67 | - | 4 x electronic | - | - | out of AUX | 1 x M12 cable socket, straight, 5 poles | - | 2 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | to connect general-purpose display banner K50 Pro to ASi | BWU4087Active Distributor ASi, IP67, 4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP20 | 4 | - | - | out of AUX | - | 8 x push in terminals | - | no | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3349Active Distributor ASi, IP20, 4I | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP20 | 3 | 1 x electronic | - | out of AUX | out of AUX | 8 x push in terminals | - | no | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3414Active Distributor ASi, IP20, 3I/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi | depth: 19 mm | IP20 | - | 4 x electronic | - | - | out of AUX | 8 x push in terminals | - | no | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 AB Slave | - | BWU3342Active Distributor ASi, IP20, 4O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 35 mm | IP67 | - | 2 x electronic | 1 x 2 channels | out of ASi | out of ASi | 1 x round cable/connecting wires + 1 x ASi addressing cable socket | - | 2 m | yes, depth: 35 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3604Active Distributor ASi Safety, IP67, 1SI/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 35 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of ASi | out of AUX | 1 x round cable/connecting wires | - | 1 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | - | BWU3425Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 35 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of ASi | out of AUX | 1 x M12 cable socket, straight, 8 poles | - | 1 m | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | - | BWU3750Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 2 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight 8 poles + 1 x M12 cable socket, straight, 5 poles | - | 10 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Leuze MLC530SPG (operation mode 5) to ASi | BWU3718Active Distributor ASi Safety, IP67, 1SI/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of ASi | out of ASi | 2 x round cables/connecting wires | - | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3249Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | - | 1 x 2 channels | out of ASi | - | 2 x round cables/connecting wires | - | 10 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3600Active Distributor ASi Safety, IP67, 1SI | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | 1 | 1 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | - | 5 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Pilz PSENslock, PSENcode to ASi | BWU3721Active Distributor ASi Safety, IP67, 1SI/1I/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | 1 | 1 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Pilz PSENslock, PSENcode to ASi | BWU3488Active Distributor ASi Safety, IP67, 1SI/1I/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | 1 | 1 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Schmersal AZM400 to ASi | BWU3565Active Distributor ASi Safety, IP67, 1SI/1I/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | 1 | 1 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Schmersal AZM200 / AZM201 / AZM300 / MZM100 to ASi | BWU3635Active Distributor ASi Safety, IP67, 1SI/1I/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 2 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight, 8 poles | - | 2 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Leuze MLD530-RT3M (operation mode 5) to ASi | BWU3719Active Distributor ASi Safety, IP67, 1SI/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 2 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x round cable/connecting wires | - | 2 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Leuze MLD530-RT3M to ASi | BWU4166Active Distributor ASi Safety, IP67, 1SI/2O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of ASi | out of ASi | 1 x round cable/connecting wires | - | 10 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3599Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of ASi | out of ASi | 1 x round cable/connecting wires | - | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3248Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of ASi | out of ASi | 1 x M12 cable socket, angled, 8 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3796Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of ASi | out of ASi | 1 x M12 cable socket, straight, 8 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU4702Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, angled, 5 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | - | BW3299Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight, 5 poles | - | 5 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | - | BWU3627Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | 1 x electronic | 1 x 2 channels | out of AUX | out of AUX | 1 x M12 cable socket, straight, 5 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 Single Slave | to connect Euchner MGB / Sick STR1-SASMOAC5 to ASi | BWU3376Active Distributor ASi Safety, IP67, 1SI/1O | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | - | 1 x 2 channels | out of ASi | - | 1 x round cable/connecting wires | - | 0,30 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3373Active Distributor ASi Safety, IP67, 1SI | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | - | 1 x 2 channels | out of ASi | - | 1 x M8 cable socket, straight, 4 poles | - | 0,20 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | to connect Sick RE13-SA84 / RE13-SAC / RE23-SAC / RE23-SA84 to ASi | BWU3553Active Distributor ASi Safety, IP67, 1SI | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | - | 1 x 2 channels | out of ASi | - | 1 x M12 cable socket, angled, 5 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3413Active Distributor ASi Safety, IP67, 1SI | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP67 | - | - | 1 x 2 channels | out of ASi | - | 1 x M12 cable socket, straight, 5 poles | - | 1 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU3626Active Distributor ASi Safety, IP67, 1SI | |||||||||||||||||||||||||||||||||
![]() | Active distributor ASi Safety | depth: 19 mm | IP20 | - | - | 1 x 2 channels | out of ASi | - | 1 x M12 cable socket, straight, 5 poles | - | 2 m | yes, depth: 19 mm | 1 x ASi | ASi profile cable | 1 Single Slave | - | BWU4701Active Distributor ASi Safety, IP67, 1SI |
ASi Slaves/IO-Link Master: Active Distributors, IP67
- IO-Link ports class A
- IO-Link ports class B
Figure | Type | Model | Number of IO-Link Ports | Port class A (M12): Pin 4 configurable (IO-Link/DI/DO), additional digital input at pin 2. Compatible with 3 pol IO-Link devices (M8). Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8). | Port class B (M12): Pin 4 configurable (IO-Link/DI/DO), additional power supply (galvanically isolated) for IO-Link devices at pins 2 and 5. Compatible with 3 pol IO-Link devices (M8). Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8). | IO-Link and additional inputs/outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs can neither be connected to earth nor to external potential. | Connection via M12: For IO-Link ports class B the supply of actuators is provided by an additional (galvanically isolated) power supply by AUX (auxiliary 24 V power) via Pin 2 (P24) and Pin 5 (N24). Connection via clamps: If connected IO-Link slaves with IO-Link ports class B need a higher current consumption, additionally they can be supplied directly via the power supply. | PUR line, oil resistant. Further connection options are available on request.
| Under normal conditions (no bus termination or repeater), the permissible total length of the ASi segment is max. 100 m. The calculation should take into consideration that the length of the connection cable (round cable) for each connected passive distributor must be doubled. In the case of the active distributors (ASi slaves) however only the one ASi profile cable is counted. | COM1 = 4.8 kBaud COM2 = 38.4 kBaud COM3 = 230.4 kBaud (optional according to Specification V1.0)
An IO-Link device supports only one of the defined data transmission rates. According to Specification V1.1, the IO-Link master supports all data transmission rates and adapts itself automatically to the data transmission rate supported by the device. | IO-Link specification | Modules with a flat housing design and with cables which exit the sides make these ideal for installation in cable ducts, cable channels, cable troughs, cable rails or cable trays. Please note the respective housing depth for your particular installation. | Profile cable connection | The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Active distributor ASi-5 | ASi slave/IO-Link master | 2 | 1 | 1 | out of AUX | out of AUX | 2 x M12 cable sockets, straight, 5 poles | 1 m | COM1 / COM2 / COM3 | V1.1 | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 ASi-5 Slave | BWU4077Active Distributor ASi-5/IO-Link Master with 2 Ports, IP67, M12, 1 IO-Link Port Class A/1 IO-Link Port Class B | ||||||||||||||||||||
![]() | Active distributor ASi-5 | ASi slave/IO-Link master | 1 | - | 1 | out of AUX | out of AUX | 1 x M12 cable socket, straight, 5 poles | 1 m | COM1 / COM2 / COM3 | V1.1 | yes, depth: 35 mm | 1 x ASi, 1 x AUX | ASi profile cable | 1 ASi-5 Slave | BWU4088Active Distributor ASi-5/IO-Link Master with 1 Port, IP67, M12, 1 IO-Link Port Class B |
Analog Modules ASi: IP65/IP67, M12
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs analog | Outputs analog | either as a single–wiring, Y–wiring or mixed-wiring.
| inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 x 4 … 20 mA | - | Signal at pin2/pin4 | out of ASi | - | 2 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3100ASi Analog Input Module, IP67, M12, 2AI (4…20mA) | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 x 0 ... 10 V | - | Signal at pin2/pin4 | out of ASi | - | 2 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3102ASi Analog Input Module, IP67, M12, 2AI (0…10V) | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | 2 x Pt100 | - | Signal at pin2/pin4 | out of ASi | - | 2 x M12 sockets, 5 poles | ASi profile cable | 1 AB Slave | BWU3104ASi Analog Input Module, IP67, M12, 2AI (Pt100) | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | - | 2 x 0 ... 20 mA | Signal at pin1/pin3 | - | out of AUX | 2 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU3105ASi Analog Output Module, IP67, M12, 2AO (0...20mA) | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | - | 2 x 0 ... 20 mA | Signal at pin2/pin4 | - | out of AUX | 2 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU3106ASi Analog Output Module, IP67, M12, 2AO (0...20mA) | |||||||||||||||||||||||||||||||||
![]() | IP67, 4 x M12 | 4 x M12 | IP67 | - | 2 x 0 … 10 V | Signal at pin1/pin3 | - | out of AUX | 2 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU3107ASi Analog Output Module, IP67, M12, 2AO (0...10V) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | 1 x 4 … 20 mA/0 … 10 V | 1 x 0 ... 20 mA/0 ... 10 V | Signal In at pin2/pin4, signal Out at pin1/pin3 | out of AUX | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 2-4 Single Slaves | BWU1853ASi Analog I/O Module, IP65, M12, 1AI (4...20mA/0...10V)/1AO (0...20mA/0...10V) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | 4 x 4 … 20 mA | - | Signal at pin2/pin4 | out of ASi or out of AUX, auto switching | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU1359ASi Analog Input Module, IP65, M12, 4AI (4…20mA) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | 4 x 0 ... 10 V | - | Signal at pin2/pin4 | out of ASi or out of AUX, auto switching | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU1360ASi Analog Input Module, IP65, M12, 4AI (0...10V) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | 4 x Pt100, 2/4 wire mode | - | Signal at pin2/pin4 | out of ASi | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU1363ASi Analog Input Module, IP65, M12, 4AI (Pt100, 2/4 wire mode) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | 4 x Pt100, 2/3 wire mode | - | Signal at pin2/pin4 | out of ASi | - | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU2532ASi Analog Input Module, IP65, M12, 4AI (Pt100, 2/3 wire mode) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | - | 4 x 0 … 20 mA | Signal at pin1/pin3 | - | out of AUX | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU1722ASi Analog Output Module, IP65, M12, 4AO (0...20mA) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | - | 4 x 0 … 20 mA | Signal at pin1/pin3 | - | out of ASi or out of AUX, auto switching | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU1361ASi Analog Output Module, IP65, M12, 4AO (0...20mA) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | - | 4 x 0 ... 10 V | Signal at pin1/pin3 | - | out of ASi or out of AUX, auto switching | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU1362ASi Analog Output Module, IP65, M12, 4AO (0...10V) | |||||||||||||||||||||||||||||||||
![]() | IP65, 4 x M12, width: 90 mm | width: 90 mm | IP65 | - | 4 x 0 … 10 V; 24 V, 0 V via M12 | Signal at pin1/pin3 | - | out of ASi or out of AUX, auto switching | 4 x M12 sockets, 5 poles | ASi profile cable | 1 Single Slave | BWU2857ASi Analog Output Module, IP65, M12, 4AO (0...10V; 24V/0V via M12) | |||||||||||||||||||||||||||||||||
![]() | IP67, 8 x M12 | 8 x M12 | IP67 | 2 x Pt100 | - | Signal at pin2/pin4 | out of AUX | out of AUX | 8 x M12 sockets, 5 poles | ASi profile cable | 2 AB Slaves | BWU2313ASi Analog Input Module, IP67, M12, 2AI (Pt100)/4I/4O |
Analog Modules ASi: IP65, PG
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs analog | Outputs analog | inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP65, 3 x PG | 3 x PG | IP65 | 2 x 4 … 20 mA | - | selectable, out of ASi or out of AUX, Default out of ASi | - | 3 x PG cable connectors | ASi profile cable | 1 Single Slave | BWU1232ASi Analog Input Module, IP65, PG, 2AI (4…20mA) | ||||||||||||||||||||
![]() | IP65, 3 x PG | 3 x PG | IP65 | 2 x 0 ... 10 V | - | selectable, out of ASi or out of AUX, Default out of ASi | - | 3 x PG cable connectors | ASi profile cable | 1 Single Slave | BWU1233ASi Analog Input Module, IP65, PG, 2AI (0…10V) | ||||||||||||||||||||
![]() | IP65, 3 x PG | 3 x PG | IP65 | Load cell | - | out of ASi | - | 3 x PG cable connectors | ASi profile cable | 1 Single Slave | BWU2240ASi Analog Input Module, IP65, PG, load cell | ||||||||||||||||||||
![]() | IP65, 3 x PG | 3 x PG | IP65 | - | 2 x 0 ... 20 mA | - | selectable, out of ASi or out of AUX, default out of ASi | 3 x PG cable connectors | ASi profile cable | 1 Single Slave | BWU1234ASi Analog Output Module, IP65, PG, 2AO (0...20mA) | ||||||||||||||||||||
![]() | IP65, 3 x PG | 3 x PG | IP65 | - | 2 x 0 … 10 V | - | selectable, out of ASi or out of AUX, default out of ASi | 3 x PG cable connectors | ASi profile cable | 1 Single Slave | BWU1235ASi Analog Output Module, IP65, PG, 2AO (0...10V) | ||||||||||||||||||||
![]() | IP65, 8 x PG | 8 x PG | IP65 | 4 x Pt100 | - | out of ASi | - | 8 x PG cable connectors | ASi profile cable | 1 Single Slave | BWU1254ASi Analog Input Module, IP65, PG, 4AI (Pt100) | ||||||||||||||||||||
![]() | IP65, 8 x PG | 8 x PG | IP65 | 4 x Pt1000 | - | out of ASi | - | 8 x PG cable connectors | ASi profile cable | 1 Single Slave | BWU1509ASi Analog Input Module, IP65, PG, 4AI (Pt1000) |
Digital Modules ASi: IP20, 22,5 mm
- Cost efficient solution in IP20, 22,5 mm
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | "Control cabinet": "Decentralized control cabinet": without additional patch terminals or the module has an extremely flat design. | Inputs digital | Outputs digital | inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP20, 22,5 mm x 50 mm, 4 x COMBICON | 4 x COMBICON | IP20 | decentralized control cabinet | 4 | 4 x electronic | out of ASi | out of ASi | clamps | clamps | 1 AB Slave | BWU2783ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 50 mm, 4 x COMBICON | 4 x COMBICON | IP20 | decentralized control cabinet | 4 | 4 x electronic | out of ASi | out of ASi | clamps | clamps | 1 Single Slave | BWU3272ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 50 mm, 4 x COMBICON | 3 x COMBICON | IP20 | decentralized control cabinet | 4 | - | out of ASi | - | clamps | clamps | 1 AB Slave | BWU3747ASi Digital Input Module, IP20, 4I | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | decentralized control cabinet | 4 | 4 x electronic | out of AUX | out of AUX | clamps | clamps | 1 AB Slave | BWU3842ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | control cabinet | 4 | 4 x electronic | out of AUX | out of AUX | clamps | clamps | 1 AB Slave | BWU3559ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | control cabinet | 4 | 3 x electronic | out of AUX | out of AUX | clamps | clamps | 1 AB Slave | BWU3733ASi Digital I/O Module, IP20, 4I/3O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 4 x COMBICON | 3 x COMBICON | IP20 | control cabinet | 4 | - | out of AUX | - | clamps | clamps | 1 AB Slave | BWU2723ASi Digital Input Module, IP20, 4I | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 4 x COMBICON | 4 x COMBICON | IP20 | control cabinet | 4 | 4 x electronic | out of AUX | out of AUX | clamps | clamps | 1 AB Slave | BWU1938ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 4 x COMBICON | 4 x COMBICON | IP20 | control cabinet | 4 | 4 x electronic | out of AUX | out of AUX | clamps | clamps | 1 Single Slave | BWU2759ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 4 x COMBICON | 4 x COMBICON | IP20 | control cabinet | 8 | - | out of AUX | - | clamps | clamps | 2 AB Slaves | BWU2721ASi Digital Input Module, IP20, 8I | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 4 x COMBICON | 4 x COMBICON | IP20 | decentralized control cabinet | 4 | - | out of AUX | - | clamps | clamps | 1 AB Slave | BWU3266ASi Digital Input Module, IP20, 4I | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 4 x COMBICON | 4 x COMBICON | IP20 | decentralized control cabinet | 4 | - | out of ASi | - | clamps | clamps | 1 AB Slave | BWU3265ASi Digital Input Module, IP20, 4I | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 4 | 3 x relay | out of ASi | - | clamps | clamps | 1 AB Slave | BWU3878ASi Digital I/O Module, IP20, 4I/3RO | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 4 | 4 x relay | out of ASi | - | clamps | clamps | 1 Single Slave | BWU3435ASi Digital I/O Module, IP20, 4I/4RO | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 4 | 4 x relay | out of ASi | - | clamps | clamps | 1 Single Slave (S-7.0.F.E) | BWU3658ASi Digital I/O Module, IP20, 4I/4RO | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 4 | 4 x relay | out of ASi | - | clamps | clamps | 1 AB Slave | BWU3549ASi Digital I/O Module, IP20, 4I/4RO | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON, ASi-5 | 6 x COMBICON | IP20 | control cabinet | 16 | - | out of AUX | - | clamps | clamps | 1 ASi-5 Slave | BWU3874ASi-5 Digital Input Module, IP20, 16I | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON, ASi-5 | 6 x COMBICON | IP20 | control cabinet | 8 | - | out of AUX | - | clamps | clamps | 1 ASi-5 Slave | BWU3873ASi-5 Digital Input Module, IP20, 8I | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON, ASi-5 | 6 x COMBICON | IP20 | control cabinet | 8 | 8 x electronic | out of AUX | out of AUX | clamps | clamps | 1 ASi-5 Slave | BWU3872ASi-5 Digital I/O Module, IP20, 8I/8O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 8 | 8 x electronic | out of AUX | out of AUX | clamps | clamps | 2 AB Slaves | BWU2490ASi Digital I/O Module, IP20, 8I/8O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 8 | 8 x electronic | out of AUX | out of AUX | clamps | clamps | 2 Single Slaves | BWU2800ASi Digital I/O Module, IP20, 8I/8O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 8 (NPN) | 8 x electronic (NPN) | out of AUX | out of AUX | clamps | clamps | 2 AB Slaves | BWU3359ASi Digital I/O Module, IP20, 8I (NPN)/8O (NPN) | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | control cabinet | 8 | 8 x electronic | out of ASi | out of AUX | clamps | clamps | 2 AB Slaves | BWU3364ASi Digital I/O Module, IP20, 8I/8O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | decentralized control cabinet | 4 | 4 x electronic | out of AUX | out of AUX | clamps | clamps | 1 AB Slave | BWU3268ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | decentralized control cabinet | 4 | 4 x electronic | out of ASi | out of AUX | clamps | clamps | 1 AB Slave | BWU3267ASi Digital I/O Module, IP20, 4I/4O | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON | 6 x COMBICON | IP20 | decentralized control cabinet | 4 | 4 x electronic | out of ASi | out of AUX | clamps | clamps | 1 Single Slave | BWU3754ASi Digital I/O Module, IP20, 4I/4O |
ASi Slaves/IO-Link Masters: IP20, 22,5 mm
- Cost efficient solution in IP20, 22,5 mm
- IO-Link ports class A
- IO-Link ports class B
- If connected IO-Link devices with port class B (M12) require an andditional power supply, they have to be supplied directly via a separate power supply.
Figure | Type | Model | "Control cabinet": "Decentralized control cabinet": without additional patch terminals or the module has an extremely flat design. | Number of IO-Link Ports | Port class A (M12): Pin 4 configurable (IO-Link/DI/DO), additional digital input at pin 2. Compatible with 3 pol IO-Link devices (M8). Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8). | Port class B (M12): Pin 4 configurable (IO-Link/DI/DO), additional power supply (galvanically isolated) for IO-Link devices at pins 2 and 5. Compatible with 3 pol IO-Link devices (M8). Configurable terminals: Terminal assignment (C/Q, L+, L-, I) compatible with pin assigment of IO-Link port class A (M12). Connected IO-Link devices with port class B (M12) with a higher current consumption have to be supplied directly via a separate power supply. Compatible with 3 pol IO-Link devices (M8). | IO-Link and additional inputs/outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs can neither be connected to earth nor to external potential. | Connection via M12: For IO-Link ports class B the supply of actuators is provided by an additional (galvanically isolated) power supply by AUX (auxiliary 24 V power) via Pin 2 (P24) and Pin 5 (N24). Connection via clamps: If connected IO-Link slaves with IO-Link ports class B need a higher current consumption, additionally they can be supplied directly via the power supply. | COM1 = 4.8 kBaud COM2 = 38.4 kBaud COM3 = 230.4 kBaud (optional according to Specification V1.0)
An IO-Link device supports only one of the defined data transmission rates. According to Specification V1.1, the IO-Link master supports all data transmission rates and adapts itself automatically to the data transmission rate supported by the device. | IO-Link specification | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON, ASi-5 | ASi slave/IO-Link master | control cabinet | 4 | configurable terminals | configurable terminals | out of AUX | - | COM1 / COM2 / COM3 | V1.1 | clamps | clamps | 1 ASi-5 Slave | BWU3843ASi-5 Slave/IO-Link Master with 4 Ports, IP20 |
ASi Counter Modules,IP20, 22,5 mm
- Conter input 4 x 2 channels or 4 x 1 channel, depending on configuration
- Pulse counter
- Cost efficient solution in IP20, 22,5 mm
Figure | Type | Model | Inputs digital | Range of value | counting rate | inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP20, 22,5 mm x 114 mm, 6 x COMBICON, ASi-5 | counter module, pulse counter | 4 x counter inputs | -32768 ... 32767 dec. | max. 250 kHz | out of AUX | clamps | clamps | 1 ASi-5 Slave | BWU3875ASi-5 Counter Module, IP20, 22,5 mm |
Digital Modules ASi in Stainless Steel, IP20
- Robust, Stainless Steel in IP20
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs digital | Outputs digital | inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | Stainless Steel in IP20, depth: 45 mm | depth: 45 mm | IP20 | 4 | 4 x relay | out of ASi | - | clamps | clamps | 1 Single Slave | BW1926ASi Digital I/O Module in Stainless Steel, IP20, 4I/4RO | ||||||||||||||||||||
![]() | Stainless Steel in IP20, depth: 45 mm | depth: 45 mm | IP20 | 4 | 3 x relay | out of ASi | - | clamps | clamps | 1 AB Slave | BW1808ASi Digital I/O Module in Stainless Steel, IP20, 4I/3RO | ||||||||||||||||||||
![]() | Stainless Steel in IP20, depth: 45 mm | depth: 45 mm | IP20 | 4 | 4 x electronic | out of AUX | out of AUX | clamps | clamps | 1 AB Slave | BW1907ASi Digital I/O Module in Stainless Steel, IP20, 4I/4O | ||||||||||||||||||||
![]() | Stainless Steel in IP20, depth: 45 mm | depth: 45 mm | IP20 | 4 | 4 x electronic | out of AUX | out of AUX | clamps | clamps | 1 Single Slave | BWU2565ASi Digital I/O Module in Stainless Steel, IP20, 4I/4O | ||||||||||||||||||||
![]() | Stainless Steel in IP20, depth: 45 mm | depth: 45 mm | IP20 | 8 | - | out of AUX | - | clamps | clamps | 2 AB Slaves | BWU2077ASi Digital Input Module in Stainless Steel, IP20, 8I | ||||||||||||||||||||
![]() | Stainless Steel in IP20, depth: 90 mm | depth: 90 mm | IP20 | 4 | 4 x relay | out of ASi | - | clamps | clamps | 1 Single Slave | BW2555ASi Digital I/O Module in Stainless Steel, IP20, 4I/4RO | ||||||||||||||||||||
![]() | Stainless Steel in IP20, depth: 90 mm | depth: 90 mm | IP20 | 8 | - | out of AUX | - | clamps | clamps | 2 AB Slaves | BW2556ASi Digital Input Module in Stainless Steel, IP20, 8I |
Analog Modules ASi: IP20
Figure | Type | Housing | "IP20": "IP40": Protected against solid foreign bodies having a diameter of 1.0 mm or larger, protected against access with a wire, no protection against water. "IP54": Protection against dust in damaging amounts, complete protection against contact, protection against splashing water in any angle.
Dust-tight, full protection against contact, protection against temporary immersion. | Inputs analog | Outputs analog | inputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, inputs shall not be connected to earth or to external potential. | Electronic outputs are supplied by ASi or by AUX (auxiliary 24 V power). If supplied by ASi, outputs shall not be connected to earth or to external potential.
For relay outputs the relay contacts are initiated from ASi. The load circuit is powered externally as specified in the data sheet. | PUR line, oil resistant. Further connection options are available on request.
| The connection to ASi as well to AUX (auxiliary 24 V power) is made via yellow resp. black ASi profile cable with piercing technology or via M12 socket (in IP20 via clamps).
| AB Slave (max. 62 AB Slaves/ASi network), 2 AB Slaves (max. 31 modules with 2 AB Slaves), Single Slaves (max. 31 Single Slaves/ASi network), ASi-5 Slave (max. 62 ASi-5 Slaves/ASi network), mixed use allowed. | Article No. | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | 2 x 4 ... 20 mA/2 x 0 … 10 V | - | selectable, out of ASi or out of AUX, Default out of ASi | - | clamps | clamps | 1 AB Slave | BWU1897ASi Analog Input Module, IP20, 2AI (4...20mA/0…10V) | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | 2 x 4 ... 20 mA/2 x 0 … 10 V | - | selectable, out of ASi or out of AUX, Default out of ASi | - | clamps | clamps | 1 Single Slave | BWU1345ASi Analog Input Module, IP20, 2AI (4...20mA/0…10V) | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | - | 2 x 0 … 20 mA/2 x 0 …10 V | - | selectable, out of ASi or out of AUX, default out of ASi | clamps | clamps | 1 Single Slave | BWU1412ASi Analog Output Module, IP20, 2AO (0...20mA/0...10V) | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | - | 2 x 0 … 20 mA/2 x 0 …10 V | - | selectable, out of ASi or out of AUX, default out of AUX | clamps | clamps | 1 Single Slave | BWU1727ASi Analog Output Module, IP20, 2AO (0...20mA/0...10V) | ||||||||||||||||||||
![]() | IP20, 22,5 mm x 92 mm, 4 x COMBICON | 4 x COMBICON | IP20 | - | 2 x +-10 V | - | out of AUX | clamps | clamps | 1 Single Slave | BWU2224ASi Analog Output Module, IP20, 2AO (+-10V) | ||||||||||||||||||||
![]() | IP20, 25 mm x 105 mm, 6 x COMBICON | 6 x COMBICON | IP20 | 4 x 4 … 20 mA | - | out of ASi or out of AUX, auto switching | - | clamps | clamps | 1 Single Slave | BWU1364ASi Analog Input Module, IP20, 4AI (4…20mA) | ||||||||||||||||||||
![]() | IP20, 25 mm x 105 mm, 6 x COMBICON | 6 x COMBICON | IP20 | 4 x 0 ... 10 V | - | out of ASi or out of AUX, auto switching | - | clamps | clamps | 1 Single Slave | BWU1365ASi Analog Input Module, IP20, 4AI (0...10V) | ||||||||||||||||||||
![]() | IP20, 25 mm x 105 mm, 6 x COMBICON | 6 x COMBICON | IP20 | 4 x Pt100 | - | out of ASi | - | clamps | clamps | 1 Single Slave | BWU1368ASi Analog Input Module, IP20, 4AI (Pt100) | ||||||||||||||||||||
![]() | IP20, 25 mm x 105 mm, 6 x COMBICON | 6 x COMBICON | IP20 | 4 x thermocouple type J | - | out of ASi | - | clamps | clamps | 1 Single Slave | BWU1933ASi Analog Input Module, IP20, 4AI (thermocouple type J) | ||||||||||||||||||||
![]() | IP20, 25 mm x 105 mm, 6 x COMBICON | 6 x COMBICON | IP20 | 4 x thermocouple type K | - | out of ASi | - | clamps | clamps | 1 Single Slave | BWU2243ASi Analog Input Module, IP20, 4AI (thermocouple type K) | ||||||||||||||||||||
![]() | IP20, 25 mm x 105 mm, 6 x COMBICON | 6 x COMBICON | IP20 | - | 4 x 0 … 20 mA | - | out of ASi or out of AUX, auto switching | clamps | clamps | 1 Single Slave | BWU1366ASi Analog Output Module, IP20, 4AO (0...20mA) | ||||||||||||||||||||
![]() | IP20, 25 mm x 105 mm, 6 x COMBICON | 6 x COMBICON | IP20 | - | 4 x 0 ... 10 V | - | out of ASi or out of AUX, auto switching | clamps | clamps | 1 Single Slave | BWU1367ASi Analog Output Module, IP20, 4AO (0...10V) |