Safety Monitor

The Safety Monitor enables safe transmission and processing of safety relevant data from safety input modules and safe shut-off of safety output modules remotely over ASi right where the potentially hazardous motion takes place. And always PLe compliant.

Bihl+Wiedemann offers the Safety Monitor for ASi Safety at Work as a stand-alone device for expanding existing ASi circuits with safety modules. For new systems we can provide our ASi-3 resp. ASi-5/ASi-3 gateways with integrated Safety Monitor and interfaces for the most commonly used automation systems using the most efficient method for safely constructing 1 or 2 ASi circuits at the same time. Even large applications with up to 1922 safety I/Os can be implemented with these devices using our “Safe Link over Ethernet” technology by connecting multiple gateways safely over Ethernet/Profinet.

For small applications with three or more safe signals you should consider our Safety Basic Monitor, a compact safety controller without gateway but with configurable status outputs. The module allows for universal expansion and is also ideal as a head station for special safety applications.

 

Safety Basic Monitors

  • Safety controllers, compact safety controller, programmable safety components
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2852ASi monitorsSafe Link3 x 2 channels, input 3 optional for speed monitor (up to 4 kHz)2 release circuits, 2 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
BWU2700ASi monitors-4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)2 release circuits, 2 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 0,5 A/ASi network, max. 8 A with ASi power supply
BW2512ASi monitors-4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)2 release circuits, 2 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 0,5 A/ASi network, max. 8 A with ASi power supply

 

 

Safety Basic Monitors, compatible as replacement with ASi Consortium Safety Monitor

  • Safety controllers, compact safety controller, programmable safety components
  • Compatible as replacement with ASi Consortium Safety Monitor
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2567ASi monitors-4 x 2 channels, inputs 3+4, compatible as replacement with consortial monitor2 release circuits, 2 x electronic safe outputsASi-3 compatible1 ASi network, no ASi Master, ASi Monitorno, max. 8 A/ASi network

 

 

Safety, PROFINET

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large systems
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2828PROFINETSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 4 A/ASi network
BWU2798PROFINETSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network
BWU3367PROFINETPROFIsafe (F-CPU) + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 4 A/ASi network
BWU2794PROFINETPROFIsafe (F-CPU)3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network
BWU3674PROFINET, OPC UAPROFIsafe (F-CPU) + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3862PROFINET, OPC UAPROFIsafe (F-CPU) + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible1 ASi network, 1 ASi-5/ASi-3 Masteryes, max. 4 A/ASi network
BWU4000PROFINET, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3863PROFINET, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible1 ASi network, 1 ASi-5/ASi-3 Masteryes, max. 4 A/ASi network
BWU3833PROFINET, OPC UAPROFIsafe (F-CPU) + Safe Link--ASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU4018PROFINET, OPC UAPROFIsafe (F-CPU) + Safe Link--ASi-5 + ASi-3 compatible1 ASi network, 1 ASi-5/ASi-3 Masteryes, max. 4 A/ASi network
BWU3998PROFINET, OPC UASafe Link--ASi-5 + ASi-3 compatible1 ASi network, 1 ASi-5/ASi-3 Masteryes, max. 4 A/ASi network

 

 

Safety, EtherNet/IP + ModbusTCP

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large systems
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU3683EtherNet/IP + ModbusTCP, OPC UACIP Safety over EtherNet/IP + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 4 A/ASi network
BWU3543EtherNet/IP + ModbusTCPSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 4 A/ASi network
BWU3544EtherNet/IP + ModbusTCPSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersno, max. 8 A/ASi network, redundant supply
BWU3542EtherNet/IP + ModbusTCPSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network
BWU3857EtherNet/IP + ModbusTCP, OPC UACIP Safety over EtherNet/IP + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3825EtherNet/IP + ModbusTCP, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3866EtherNet/IP + ModbusTCP, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible1 ASi network, 1 ASi-5/ASi-3 Masteryes, max. 4 A/ASi network

 

 

Safety, EtherCAT

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large systems
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2944EtherCATSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 4 A/ASi network
BWU2797EtherCATSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network
BWU3858EtherCAT, OPC UAFSoE + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3583EtherCAT, OPC UAFSoE + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible1 ASi network, 1 ASi-5/ASi-3 Masteryes, max. 4 A/ASi network
BWU3991EtherCAT, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible1 ASi network, 1 ASi-5/ASi-3 Masteryes, max. 4 A/ASi network

 

 

Safety, POWERLINK

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large applications
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU3865POWERLINK, OPC UAopenSAFETY over POWERLINK + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3828POWERLINK, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3176POWERLINKSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 4 A/ASi network
BWU3177POWERLINKSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network

 

 

Safety, Sercos

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large systems
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU3861Sercos, OPC UAsafe Schneider drives over Sercos + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3860Sercos, OPC UACIP Safety over Sercos + Safe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network
BWU3845Sercos, OPC UACIP Safety over Sercos + Safe Link--ASi-5 + ASi-3 compatible2 ASi networks, 2 ASi-5/ASi-3 Mastersyes, max. 4 A/ASi network

 

 

Safety, PROFIBUS

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large applications
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2819PROFIBUSPROFIsafe (F-CPU)3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network
BWU2822PROFIBUSSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 4 A/ASi network
BWU2793PROFIBUSSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network

 

 

Safety, BACnet/IP

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large applications
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU4780BACnet/IP, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersyes, max. 8 A/ASi network
BWU4001BACnet/IP, OPC UASafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible2 ASi networks, 2 ASi-3 Mastersno, max. 8 A/ASi network, redundant supply

 

 

Safety, DeviceNet

Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2972DeviceNetSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network

 

 

Safety, CANopen

Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2804CANopenSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network

 

 

Safety, CC-Link

  • Safety diagnostics in real-time
  • Cost-optimized solution for medium-size and large systems
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BWU2833CC-LinkSafe Link3 x 2 channels6 release circuits, 6 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 4 A/ASi network

 

Starter Kits

  • Fully assembled and wired in a practical case
Figure

 

 

Communication interface between fieldbus and gateway:

interfaces for standardized fieldbus systems in industrial automation.

PROFIBUS ASi gateway: interface for a PROFIBUS fieldbus

 

PROFIBUS ASi Basic gateway: interface for a PROFIBUS fieldbus

PROFIBUS ASi IP65 gateway: interface for a PROFIBUS fieldbus
PROFINET ASi gateway: interface for a PROFINET fieldbus

EtherNet/IP+ Modbus TCP ASi gateway: interface for an EtherNet/IP+ ModbusTCP fieldbus

BACnet/IP ASi gateway: interface for a BACnet/IP fieldbus
DeviceNet ASi gateway: interface for a DeviceNet fieldbus
ControlLogix ASi gateway: interface for the ControlLogix backplane

Compact-/MicroLogix ASi gateway: interface for the Compact-/MicroLogix backplane
EtherCat ASi gateway: interface for an EtherCat fieldbus

POWERLINK ASi gateway: interface for an POWERLINK fieldbus
CC-Link ASi gateway:
interface for a CC-Link fieldbus
CANopen ASi gateway: interface for a CANopen fieldbus
RS 485 Modbus ASi gateway: interface for a Modbus/RTU; RS 485 fieldbus

OPC UA server: interface for the OPC UA communication

 

Fieldbus interface
Safety communication Inputs Safety, SIL 3, Cat. 4 Outputs Safety, SIL 3, cat. 4 ASi-5/ASi-3
Standard devices

"Single Master":

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master":

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

Safety devices

"Single Master" :

1 ASi network, 1 ASi-5/ASi-3 Master.

1 ASi network, 1 ASi-3 Master.

"Double Master" :

2 ASi networks, 2 ASi-5/ASi-3 Masters.

2 ASi networks, 2 ASi-3 Masters.

"Optional ASi Safety coupling circuit" :
2 ASi networks, 1 ASi-3 Master.

Number of ASi networks, number of ASi Master

" yes, max. 4 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


" yes, max. 8 A/ASi network ":

Data decoupling integrated in the gateway. Cost-effective power for 2 ASi networks with 1 power supply (optionally supply of multiple Single Gateways by 1 power supply).

Operation with short cable lengths with standard 24 V power supply possible.


"yes, optimized for 2 x NEC class 2 power supplies"

Data decoupling integrated in the gateway. Optimized for use with 2 x UL certified 30 V/3 A power supplies with power limitation <100 W (BW4223). In combination 2 separate NEC Class 2 compliant ASi circuits are created.


"no, max. 8 A/ASi network, redundant supply ":

1 ASi power supply per ASi network. Gateway is powered in normal operation from one of the two ASi power supplies.

Should one ASi power supply fail, switching to the other ASi power supply allows all the diagnostics functions to be maintained and the unaffected ASi network continues to operate.


" no, max. 8 A/ASi network ":

1 ASi power supply per ASi network.

Integrated decoupling, ASi current measurement in the gateway
Article No.
BW2512ASi monitors-4 x 2 channels, inputs 3+4 optional for speed monitor (up to 4 kHz)2 release circuits, 2 x electronic safe outputsASi-3 compatible1 ASi network, 1 ASi-3 Masteryes, max. 0,5 A/ASi network, max. 8 A with ASi power supply